Evaluation of cooling performance of thermally activated building system with evaporative cooling source for typical United States climates
Jingjuan Feng, Fred Bauman
Abstract
Open-access reader
Jingjuan Feng, Fred Bauman
Abstract
Open-access reader
Thermally activated building systems (TABS) are gaining popularity as a potentially energy efficient strategy for conditioning buildings. These systems can use large surfaces for heat exchange, and the temperature of the cooling water can be only a few degrees lower than the room air temperature. This small temperature difference allows the use of alternative cooling sources, for example, indirect/direct evaporative cooling, to possibly eliminate refrigerant cooling to reduce energy consumption. In addition, TABS allow the potential to reduce the electric power demand of the building if a night time precooling strategy is used. This research has investigated the application range of using slab-integrated hydronic radiant cooling (TABS) with a cooling tower providing chilled water as the primary way of conditioning the building. The objectives of this study were the following: 1)quantify the climatic limits of using evaporative cooling (cooling tower) for radiant ceiling slab system; 2) identify design options to expand the application; and 3) provide climate based advice for system design and operation.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Thermally activated building systems (TABS) are gaining popularity as a potentially energy efficient strategy for conditioning buildings. These systems can use large surfaces for heat exchange, and the temperature of the cooling water can be only a few degrees lower than the room air temperature. This small temperature difference allows the use of alternative cooling sources, for example, indirect/direct evaporative cooling, to possibly eliminate refrigerant cooling to reduce energy consumption. In addition, TABS allow the potential to reduce the electric power demand of the building if a night time precooling strategy is used. This research has investigated the application range of using slab-integrated hydronic radiant cooling (TABS) with a cooling tower providing chilled water as the primary way of conditioning the building. The objectives of this study were the following: 1)quantify the climatic limits of using evaporative cooling (cooling tower) for radiant ceiling slab system; 2) identify design options to expand the application; and 3) provide climate based advice for system design and operation.
Key concepts: Evaporative cooler, Radiant cooling, Cooling tower, Chiller, Environmental science, Active cooling, Chilled water, Passive cooling