2001PubMedRequires access

Evaluation of Transient and Distortion Product Otoacoustic Emissions before and after shooting practice.

Wiesław Konopka, Piotr Zalewski, Piotr Pietkiewicz

Open publisher page 33 citations

Abstract

Firearms are a common source of impulse noise that may potentially damage a hearing organ. It is not easy to predict soldiers' personal susceptibility to noise exposure. The purpose of this study was to evaluate of the transient evoked otoacoustic emission (TEOAE) and distortion-product otoacoustic emission (DPOAE) before and after shooting and compare it with conventional pure tone audiometry. Standard pure tone audiometry, tympanometry, TEOAE and DPOAE measurements were recorded before and 10-15 minutes after shooting. Ten male soldiers (20 ears) were exposed to impulse noise from automatic gunfire (15 single rounds of live ammunition). They did not use any earplugs. The reduction in amplitude of the TEOAE after shooting was 3.1 and 5.1 as SPL for 3 and 4 kHz respectively for the right ear and 4.3 dB SPL for 1 kHz and 0.6 dB SPL at 2 kHz for the left ear. The greatest reduction in DPOAE occurred at frequencies of 1.0 kHz (3.8dB SPL) and 3.0 kHz (2.9 dB SPL) for the left ear. There were no differences in the audiometric thresholds before and after shooting. Emissions appear to be more sensitive for monitoring early cochlear changes after shooting, than pure tone audiometry.

About this research paper

What this paper is about

Firearms are a common source of impulse noise that may potentially damage a hearing organ. It is not easy to predict soldiers' personal susceptibility to noise exposure. The purpose of this study was to evaluate of the transient evoked otoacoustic emission (TEOAE) and distortion-product otoacoustic emission (DPOAE) before and after shooting and compare it with conventional pure tone audiometry. Standard pure tone audiometry, tympanometry, TEOAE and DPOAE measurements were recorded before and 10-15 minutes after shooting. Ten male soldiers (20 ears) were exposed to impulse noise from automatic gunfire (15 single rounds of live ammunition). They did not use any earplugs. The reduction in amplitude of the TEOAE after shooting was 3.1 and 5.1 as SPL for 3 and 4 kHz respectively for the right ear and 4.3 dB SPL for 1 kHz and 0.6 dB SPL at 2 kHz for the left ear. The greatest reduction in DPOAE occurred at frequencies of 1.0 kHz (3.8dB SPL) and 3.0 kHz (2.9 dB SPL) for the left ear. There were no differences in the audiometric thresholds before and after shooting. Emissions appear to be more sensitive for monitoring early cochlear changes after shooting, than pure tone audiometry.

Why it matters

OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Firearms are a common source of impulse noise that may potentially damage a hearing organ. It is not easy to predict soldiers' personal susceptibility to noise exposure. The purpose of this study was to evaluate of the transient evoked otoacoustic emission (TEOAE) and distortion-product otoacoustic emission (DPOAE) before and after shooting and compare it with conventional pure tone audiometry. Standard pure tone audiometry, tympanometry, TEOAE and DPOAE measurements were recorded before and 10-15 minutes after shooting. Ten male soldiers (20 ears) were exposed to impulse noise from automatic gunfire (15 single rounds of live ammunition). They did not use any earplugs. The reduction in amplitude of the TEOAE after shooting was 3.1 and 5.1 as SPL for 3 and 4 kHz respectively for the right ear and 4.3 dB SPL for 1 kHz and 0.6 dB SPL at 2 kHz for the left ear. The greatest reduction in DPOAE occurred at frequencies of 1.0 kHz (3.8dB SPL) and 3.0 kHz (2.9 dB SPL) for the left ear. There were no differences in the audiometric thresholds before and after shooting. Emissions appear to be more sensitive for monitoring early cochlear changes after shooting, than pure tone audiometry.

Key concepts: Otoacoustic emission, Audiology, Pure tone audiometry, Audiometry, Tympanometry, Cochlea, Impulse noise, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Transient and Distortion Product Otoacoustic Emissions before and after shooting practice. — Research Paper | ScholarLens