2012Journal of Geophysical Research AtmospheresRequires access

Stratosphere‐to‐troposphere transport revealed by ground‐based lidar and ozonesonde at a midlatitude site

Shi Kuang, Michael J. Newchurch, J. Burris, Lihua Wang, Kevin R. Knupp, Guanyu Huang

Open publisher page 70 citations

Abstract

This paper presents ozone structures measured by a ground‐based ozone lidar and ozonesonde at Huntsville, Alabama, on 27–29 April 2010 originating from a stratosphere‐to‐troposphere transport event associated with a cutoff cyclone and tropopause fold. In this case, the tropopause reached 6 km and the stratospheric intrusion resulted in a 2‐km thick elevated ozone layer with values between 70 and 85 ppbv descending from the ∼306‐K to 298‐K isentropic surface at a rate of ∼5 km day−1. The potential temperature was provided by a collocated microwave profiling radiometer. We examine the corresponding meteorological fields and potential vorticity (PV) structures derived from the analysis data from the North American Mesoscale model. The 2‐PVU (PV unit) surface, defined as the dynamic tropopause, is able to capture the variations of the ozone tropopause estimated from the ozonesonde and lidar measurements. The estimated ozone/PV ratio, from the measured ozone and model derived PV, for the mixing layer between the troposphere and stratosphere is ∼41 ppbv/PVU with an uncertainty of ∼33%. Within two days, the estimated mass of ozone irreversibly transported from the stratospheric into the troposphere is between 0.07 Tg (0.9 × 1033 molecules) and 0.11 Tg (1.3 × 1033molecules) with an estimated uncertainty of 59%. Tropospheric ozone exhibited enormous variability due to the complicated mixing processes. Low ozone and large variability were observed in the mid‐troposphere after the stratospheric intrusion due to the westerly advection including the transition from a cyclonic system to an anticyclonic system. This study using high temporal and vertical‐resolution measurements suggests that, in this case, stratospheric air quickly lost its stratospheric characteristics once it is irreversibly mixed down into the troposphere.

About this research paper

What this paper is about

This paper presents ozone structures measured by a ground‐based ozone lidar and ozonesonde at Huntsville, Alabama, on 27–29 April 2010 originating from a stratosphere‐to‐troposphere transport event associated with a cutoff cyclone and tropopause fold. In this case, the tropopause reached 6 km and the stratospheric intrusion resulted in a 2‐km thick elevated ozone layer with values between 70 and 85 ppbv descending from the ∼306‐K to 298‐K isentropic surface at a rate of ∼5 km day−1. The potential temperature was provided by a collocated microwave profiling radiometer. We examine the corresponding meteorological fields and potential vorticity (PV) structures derived from the analysis data from the North American Mesoscale model. The 2‐PVU (PV unit) surface, defined as the dynamic tropopause, is able to capture the variations of the ozone tropopause estimated from the ozonesonde and lidar measurements. The estimated ozone/PV ratio, from the measured ozone and model derived PV, for the mixing layer between the troposphere and stratosphere is ∼41 ppbv/PVU with an uncertainty of ∼33%. Within two days, the estimated mass of ozone irreversibly transported from the stratospheric into the troposphere is between 0.07 Tg (0.9 × 1033 molecules) and 0.11 Tg (1.3 × 1033molecules) with an estimated uncertainty of 59%. Tropospheric ozone exhibited enormous variability due to the complicated mixing processes. Low ozone and large variability were observed in the mid‐troposphere after the stratospheric intrusion due to the westerly advection including the transition from a cyclonic system to an anticyclonic system. This study using high temporal and vertical‐resolution measurements suggests that, in this case, stratospheric air quickly lost its stratospheric characteristics once it is irreversibly mixed down into the troposphere.

Why it matters

OpenAlex reports 70 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents ozone structures measured by a ground‐based ozone lidar and ozonesonde at Huntsville, Alabama, on 27–29 April 2010 originating from a stratosphere‐to‐troposphere transport event associated with a cutoff cyclone and tropopause fold. In this case, the tropopause reached 6 km and the stratospheric intrusion resulted in a 2‐km thick elevated ozone layer with values between 70 and 85 ppbv descending from the ∼306‐K to 298‐K isentropic surface at a rate of ∼5 km day−1. The potential temperature was provided by a collocated microwave profiling radiometer. We examine the corresponding meteorological fields and potential vorticity (PV) structures derived from the analysis data from the North American Mesoscale model. The 2‐PVU (PV unit) surface, defined as the dynamic tropopause, is able to capture the variations of the ozone tropopause estimated from the ozonesonde and lidar measurements. The estimated ozone/PV ratio, from the measured ozone and model derived PV, for the mixing layer between the troposphere and stratosphere is ∼41 ppbv/PVU with an uncertainty of ∼33%. Within two days, the estimated mass of ozone irreversibly transported from the stratospheric into the troposphere is between 0.07 Tg (0.9 × 1033 molecules) and 0.11 Tg (1.3 × 1033molecules) with an estimated uncertainty of 59%. Tropospheric ozone exhibited enormous variability due to the complicated mixing processes. Low ozone and large variability were observed in the mid‐troposphere after the stratospheric intrusion due to the westerly advection including the transition from a cyclonic system to an anticyclonic system. This study using high temporal and vertical‐resolution measurements suggests that, in this case, stratospheric air quickly lost its stratospheric characteristics once it is irreversibly mixed down into the troposphere.

Key concepts: Tropopause, Troposphere, Stratosphere, Atmospheric sciences, Environmental science, Potential vorticity, Ozone, Ozone layer

Related papers

Back to paper searchBrowse research topicsOriginal source
Stratosphere‐to‐troposphere transport revealed by ground‐based lidar and ozonesonde at a midlatitude site — Research Paper | ScholarLens