2002IEEE Conference Record - Abstracts. PPPS-2001 Pulsed Power Plasma Science 2001. 28th IEEE International Conference on Plasma Science and 13th IEEE International Pulsed Power Conference (Cat. No.01CH37255)Requires access

S-band vircator with e-beam premodulation based on compact HV pulser with inductive energy store

А. М. Ефремов, S. A. Kitsanov, A. I. Klimov, S. D. Korovin, B. M. Kovalchuk, I. K. Kurkan, О. П. Кутенков, S.V. Loginov, I.V. Pegel, S. D. Polevin, A. A. Zherlitsyn

Open publisher page 0 citations

Abstract

Summary form only given, as follows. An S-band vircator with electron beam premodulation, without external magnetic field, based on a compact HV pulse generator with inductive energy store, was realized in experiment. The primary capacitor of the HV pulser was switched by means of a five-channel multigap discharger onto serially connected inductance and wire fuse. The short-circuit current of the generator was 65 kA with quarter-period of oscillation 6.6 /spl mu/s. The arising voltage made a peaking discharger operate thereby connecting the storing inductance with the electron vacuum diode of the vircator. The pulse width at the cathode could be varied within 50-150 ns using a slicer. The microwave power of the vircator was measured using calibrated dipole antennas by integrating over the radiation pattern, and a 60-dB directed coupler built in the single-mode output waveguide of the vircator. The vircator operated at the mode TE10. The output microwave power was 300 MW with 5% efficiency and 50 ns pulse width,. The generation frequency was 2.65 GHz, stable during the pulse despite the fact that the decrease in the vacuum diode impedance during the pulse was a factor of three. The generation frequency was tunable within 15% at half power level. The maximum microwave output corresponded to 20-30% excess of electron beam current above the critical one.

About this research paper

What this paper is about

Summary form only given, as follows. An S-band vircator with electron beam premodulation, without external magnetic field, based on a compact HV pulse generator with inductive energy store, was realized in experiment. The primary capacitor of the HV pulser was switched by means of a five-channel multigap discharger onto serially connected inductance and wire fuse. The short-circuit current of the generator was 65 kA with quarter-period of oscillation 6.6 /spl mu/s. The arising voltage made a peaking discharger operate thereby connecting the storing inductance with the electron vacuum diode of the vircator. The pulse width at the cathode could be varied within 50-150 ns using a slicer. The microwave power of the vircator was measured using calibrated dipole antennas by integrating over the radiation pattern, and a 60-dB directed coupler built in the single-mode output waveguide of the vircator. The vircator operated at the mode TE10. The output microwave power was 300 MW with 5% efficiency and 50 ns pulse width,. The generation frequency was 2.65 GHz, stable during the pulse despite the fact that the decrease in the vacuum diode impedance during the pulse was a factor of three. The generation frequency was tunable within 15% at half power level. The maximum microwave output corresponded to 20-30% excess of electron beam current above the critical one.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Summary form only given, as follows. An S-band vircator with electron beam premodulation, without external magnetic field, based on a compact HV pulse generator with inductive energy store, was realized in experiment. The primary capacitor of the HV pulser was switched by means of a five-channel multigap discharger onto serially connected inductance and wire fuse. The short-circuit current of the generator was 65 kA with quarter-period of oscillation 6.6 /spl mu/s. The arising voltage made a peaking discharger operate thereby connecting the storing inductance with the electron vacuum diode of the vircator. The pulse width at the cathode could be varied within 50-150 ns using a slicer. The microwave power of the vircator was measured using calibrated dipole antennas by integrating over the radiation pattern, and a 60-dB directed coupler built in the single-mode output waveguide of the vircator. The vircator operated at the mode TE10. The output microwave power was 300 MW with 5% efficiency and 50 ns pulse width,. The generation frequency was 2.65 GHz, stable during the pulse despite the fact that the decrease in the vacuum diode impedance during the pulse was a factor of three. The generation frequency was tunable within 15% at half power level. The maximum microwave output corresponded to 20-30% excess of electron beam current above the critical one.

Key concepts: Vircator, Marx generator, Electrical engineering, Microwave, Cathode ray, Physics, Pulse generator, Relativistic electron beam

Related papers

Back to paper searchBrowse research topicsOriginal source
S-band vircator with e-beam premodulation based on compact HV pulser with inductive energy store — Research Paper | ScholarLens