1998Ophthalmic surgery, lasers & imaging retinaRequires access

Changes in Anterior Chamber Depth and Intraocular Pressure After Phacoemulsification and Posterior Chamber Intraocular Lens Implantation

Osman Çekıç, Coşar Batman, Yüksel Totan, Murat Emre, Orhan Zilelioğlu

Open publisher page 38 citations

Abstract

BACKGROUND AND OBJECTIVE: To determine anterior chamber depth (ACD) and intraocular pressure (IOP) following uncomplicated cataract extraction with phacoemulsification and posterior chamber intraocular lens (IOL) implantation. PATIENTS AND METHODS: The ACDs and IOPs of 56 patients were prospectively evaluated after phacoemulsification and IOL implantation. Measurements of ACD were performed using ultrasonography and measurements of IOP were performed using a Goldmann applanation tonometer preoperatively and at 1 week and 1, 3, 6, and 9 months postoperatively. RESULTS: The mean IOP had decreased and the mean ACD had increased significantly by 1 month postoperatively (P < .03 and P < .01, respectively). Between 1 and 3 months, a significant increase in ACD (P < .05) and decrease in IOP (P < .01) was also observed. The ACD peaked (3.51 +/- 0.45 mm) and the IOP reached its lowest value (10.05 +/- 2.23 mm Hg) at 3 months postoperatively. The reduction in IOP and increase in ACD remained significant during the follow-up period, compared with the preoperative values. CONCLUSION: These results suggest that increases in ACD and decreases in IOP occur in selected patients after uncomplicated cataract extraction by phacoemulsification with IOL implantation.

About this research paper

What this paper is about

BACKGROUND AND OBJECTIVE: To determine anterior chamber depth (ACD) and intraocular pressure (IOP) following uncomplicated cataract extraction with phacoemulsification and posterior chamber intraocular lens (IOL) implantation. PATIENTS AND METHODS: The ACDs and IOPs of 56 patients were prospectively evaluated after phacoemulsification and IOL implantation. Measurements of ACD were performed using ultrasonography and measurements of IOP were performed using a Goldmann applanation tonometer preoperatively and at 1 week and 1, 3, 6, and 9 months postoperatively. RESULTS: The mean IOP had decreased and the mean ACD had increased significantly by 1 month postoperatively (P < .03 and P < .01, respectively). Between 1 and 3 months, a significant increase in ACD (P < .05) and decrease in IOP (P < .01) was also observed. The ACD peaked (3.51 +/- 0.45 mm) and the IOP reached its lowest value (10.05 +/- 2.23 mm Hg) at 3 months postoperatively. The reduction in IOP and increase in ACD remained significant during the follow-up period, compared with the preoperative values. CONCLUSION: These results suggest that increases in ACD and decreases in IOP occur in selected patients after uncomplicated cataract extraction by phacoemulsification with IOL implantation.

Why it matters

OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND AND OBJECTIVE: To determine anterior chamber depth (ACD) and intraocular pressure (IOP) following uncomplicated cataract extraction with phacoemulsification and posterior chamber intraocular lens (IOL) implantation. PATIENTS AND METHODS: The ACDs and IOPs of 56 patients were prospectively evaluated after phacoemulsification and IOL implantation. Measurements of ACD were performed using ultrasonography and measurements of IOP were performed using a Goldmann applanation tonometer preoperatively and at 1 week and 1, 3, 6, and 9 months postoperatively. RESULTS: The mean IOP had decreased and the mean ACD had increased significantly by 1 month postoperatively (P < .03 and P < .01, respectively). Between 1 and 3 months, a significant increase in ACD (P < .05) and decrease in IOP (P < .01) was also observed. The ACD peaked (3.51 +/- 0.45 mm) and the IOP reached its lowest value (10.05 +/- 2.23 mm Hg) at 3 months postoperatively. The reduction in IOP and increase in ACD remained significant during the follow-up period, compared with the preoperative values. CONCLUSION: These results suggest that increases in ACD and decreases in IOP occur in selected patients after uncomplicated cataract extraction by phacoemulsification with IOL implantation.

Key concepts: Phacoemulsification, Medicine, Ophthalmology, Intraocular pressure, Intraocular lens, Cataract extraction, Visual acuity

Related papers

Back to paper searchBrowse research topicsOriginal source
Changes in Anterior Chamber Depth and Intraocular Pressure After Phacoemulsification and Posterior Chamber Intraocular Lens Implantation — Research Paper | ScholarLens