2006PubMedRequires access

Sentinel node detection with the blue dye technique in early cervical cancer.

Verena Schwendinger, Elisabeth Müller‐Holzner, Alain G. Zeimet, Christian Marth

Open publisher page 18 citations

Abstract

OBJECTIVE: The aim of this study was to investigate the feasibility of sentinel node detection with the blue dye technique in early cervical cancer. METHODS: In a retrospective study conducted between January 2000 and February 2005, 47 women with early cervical cancer (6 patients FIGO Stage I A, 38 patients FIGO Stage I B, 2 patients FIGO Stage II A, 1 patient FIGO Stage II B) who underwent class II-III radical hysterectomy with pelvic lymphadenectomy were identified. Prior to surgery 1 ml of blue dye (lymphazurin 1%) was injected into the four quadrants of the cervix. RESULTS: The detection rate for sentinel nodes was 83% (39/47 patients). The median number of sentinel lymph nodes per patient was two. Nine patients had positive sentinel nodes. In one patient the sentinel lymph node procedure revealed to be false-negative. Positive predictive value and specificity were both 100%. The sensitivity and negative predictive value were 90% and 97%, respectively. CONCLUSIONS: Sentinel node detection has become a main field of interest in gynecological oncology. Our detection rate and sensitivity rate using the blue dye technique in cervical cancer are comparable to those in previously published data. However, recent data on a combined radioactively labeled albumin and blue dye technique show even more promising results. The clinical validity of the combined techniques must be evaluated prospectively in larger studies.

About this research paper

What this paper is about

OBJECTIVE: The aim of this study was to investigate the feasibility of sentinel node detection with the blue dye technique in early cervical cancer. METHODS: In a retrospective study conducted between January 2000 and February 2005, 47 women with early cervical cancer (6 patients FIGO Stage I A, 38 patients FIGO Stage I B, 2 patients FIGO Stage II A, 1 patient FIGO Stage II B) who underwent class II-III radical hysterectomy with pelvic lymphadenectomy were identified. Prior to surgery 1 ml of blue dye (lymphazurin 1%) was injected into the four quadrants of the cervix. RESULTS: The detection rate for sentinel nodes was 83% (39/47 patients). The median number of sentinel lymph nodes per patient was two. Nine patients had positive sentinel nodes. In one patient the sentinel lymph node procedure revealed to be false-negative. Positive predictive value and specificity were both 100%. The sensitivity and negative predictive value were 90% and 97%, respectively. CONCLUSIONS: Sentinel node detection has become a main field of interest in gynecological oncology. Our detection rate and sensitivity rate using the blue dye technique in cervical cancer are comparable to those in previously published data. However, recent data on a combined radioactively labeled albumin and blue dye technique show even more promising results. The clinical validity of the combined techniques must be evaluated prospectively in larger studies.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: The aim of this study was to investigate the feasibility of sentinel node detection with the blue dye technique in early cervical cancer. METHODS: In a retrospective study conducted between January 2000 and February 2005, 47 women with early cervical cancer (6 patients FIGO Stage I A, 38 patients FIGO Stage I B, 2 patients FIGO Stage II A, 1 patient FIGO Stage II B) who underwent class II-III radical hysterectomy with pelvic lymphadenectomy were identified. Prior to surgery 1 ml of blue dye (lymphazurin 1%) was injected into the four quadrants of the cervix. RESULTS: The detection rate for sentinel nodes was 83% (39/47 patients). The median number of sentinel lymph nodes per patient was two. Nine patients had positive sentinel nodes. In one patient the sentinel lymph node procedure revealed to be false-negative. Positive predictive value and specificity were both 100%. The sensitivity and negative predictive value were 90% and 97%, respectively. CONCLUSIONS: Sentinel node detection has become a main field of interest in gynecological oncology. Our detection rate and sensitivity rate using the blue dye technique in cervical cancer are comparable to those in previously published data. However, recent data on a combined radioactively labeled albumin and blue dye technique show even more promising results. The clinical validity of the combined techniques must be evaluated prospectively in larger studies.

Key concepts: Medicine, Radical Hysterectomy, Cervical cancer, Sentinel node, Stage (stratigraphy), Sentinel lymph node, Cervix, Lymph node

Related papers

Back to paper searchBrowse research topicsOriginal source
Sentinel node detection with the blue dye technique in early cervical cancer. — Research Paper | ScholarLens