Determination of Trace Metals in Waters by FAAS after Enrichment as Metal-HMDTC Complexes Using Solid Phase Extraction
Şerife Tokalıoğlu
Abstract
Open-access reader
Şerife Tokalıoğlu
Abstract
Open-access reader
A method has been described for the determination of Cu(Ⅱ), Pb(Ⅱ), Ni(Ⅱ), Cd(Ⅱ), Mn(Ⅱ) and Fe(Ⅲ) by flame atomic absorption spectrometry (FAAS) after preconcentration on Amberlite XAD-16 resin, using hexamethyleneammonium-hexamethylenedithiocarbamate (HMA-HMDTC) as a chelating agent, and NH3/NH4Cl buffer solution (pH 9). Influences of various analytical parameters such as pH, concentration of nitric acid, amount of analytes, diverse ions and sample volume were investigated. The relative standard deviation (RSD) and the detection limit (LOD) were found in the range of 0.8-2.9% and 0.006-0.277 ㎍/mL,respectively. Recoveries obtained by the column method were quantitative ( >95%) at optimum conditions.The method was applied to the determination of some metal ions in seawater and wastewater samples. A high preconcentration factor (about 150 for seawater and 75 for wastewater samples) and simplicity are the main advantages of this suggested method.
OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A method has been described for the determination of Cu(Ⅱ), Pb(Ⅱ), Ni(Ⅱ), Cd(Ⅱ), Mn(Ⅱ) and Fe(Ⅲ) by flame atomic absorption spectrometry (FAAS) after preconcentration on Amberlite XAD-16 resin, using hexamethyleneammonium-hexamethylenedithiocarbamate (HMA-HMDTC) as a chelating agent, and NH3/NH4Cl buffer solution (pH 9). Influences of various analytical parameters such as pH, concentration of nitric acid, amount of analytes, diverse ions and sample volume were investigated. The relative standard deviation (RSD) and the detection limit (LOD) were found in the range of 0.8-2.9% and 0.006-0.277 ㎍/mL,respectively. Recoveries obtained by the column method were quantitative ( >95%) at optimum conditions.The method was applied to the determination of some metal ions in seawater and wastewater samples. A high preconcentration factor (about 150 for seawater and 75 for wastewater samples) and simplicity are the main advantages of this suggested method.
Key concepts: Amberlite, Detection limit, Chemistry, Solid phase extraction, Seawater, Nitric acid, Extraction (chemistry), Enrichment factor