2002•Bulletin of the Korean Chemical SocietyOpen access

Determination of Trace Metals in Waters by FAAS after Enrichment as Metal-HMDTC Complexes Using Solid Phase Extraction

Şerife Tokalıoğlu

Open full text 15 citations

Abstract

A method has been described for the determination of Cu(Ⅱ), Pb(Ⅱ), Ni(Ⅱ), Cd(Ⅱ), Mn(Ⅱ) and Fe(Ⅲ) by flame atomic absorption spectrometry (FAAS) after preconcentration on Amberlite XAD-16 resin, using hexamethyleneammonium-hexamethylenedithiocarbamate (HMA-HMDTC) as a chelating agent, and NH3/NH4Cl buffer solution (pH 9). Influences of various analytical parameters such as pH, concentration of nitric acid, amount of analytes, diverse ions and sample volume were investigated. The relative standard deviation (RSD) and the detection limit (LOD) were found in the range of 0.8-2.9% and 0.006-0.277 ㎍/mL,respectively. Recoveries obtained by the column method were quantitative ( >95%) at optimum conditions.The method was applied to the determination of some metal ions in seawater and wastewater samples. A high preconcentration factor (about 150 for seawater and 75 for wastewater samples) and simplicity are the main advantages of this suggested method.

Open-access reader

About this research paper

What this paper is about

A method has been described for the determination of Cu(Ⅱ), Pb(Ⅱ), Ni(Ⅱ), Cd(Ⅱ), Mn(Ⅱ) and Fe(Ⅲ) by flame atomic absorption spectrometry (FAAS) after preconcentration on Amberlite XAD-16 resin, using hexamethyleneammonium-hexamethylenedithiocarbamate (HMA-HMDTC) as a chelating agent, and NH3/NH4Cl buffer solution (pH 9). Influences of various analytical parameters such as pH, concentration of nitric acid, amount of analytes, diverse ions and sample volume were investigated. The relative standard deviation (RSD) and the detection limit (LOD) were found in the range of 0.8-2.9% and 0.006-0.277 ㎍/mL,respectively. Recoveries obtained by the column method were quantitative ( >95%) at optimum conditions.The method was applied to the determination of some metal ions in seawater and wastewater samples. A high preconcentration factor (about 150 for seawater and 75 for wastewater samples) and simplicity are the main advantages of this suggested method.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method has been described for the determination of Cu(Ⅱ), Pb(Ⅱ), Ni(Ⅱ), Cd(Ⅱ), Mn(Ⅱ) and Fe(Ⅲ) by flame atomic absorption spectrometry (FAAS) after preconcentration on Amberlite XAD-16 resin, using hexamethyleneammonium-hexamethylenedithiocarbamate (HMA-HMDTC) as a chelating agent, and NH3/NH4Cl buffer solution (pH 9). Influences of various analytical parameters such as pH, concentration of nitric acid, amount of analytes, diverse ions and sample volume were investigated. The relative standard deviation (RSD) and the detection limit (LOD) were found in the range of 0.8-2.9% and 0.006-0.277 ㎍/mL,respectively. Recoveries obtained by the column method were quantitative ( >95%) at optimum conditions.The method was applied to the determination of some metal ions in seawater and wastewater samples. A high preconcentration factor (about 150 for seawater and 75 for wastewater samples) and simplicity are the main advantages of this suggested method.

Key concepts: Amberlite, Detection limit, Chemistry, Solid phase extraction, Seawater, Nitric acid, Extraction (chemistry), Enrichment factor

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Metals in Waters by FAAS after Enrichment as Metal-HMDTC Complexes Using Solid Phase Extraction — Research Paper | ScholarLens