2014•International Journal of Applied Power Engineering (IJAPE)Open access

Comparison of FACTS Devices for Two Area Power System Stability Enhancement using MATLAB Modelling

Jitendra Nath Rai

Open full text 3 citations

Abstract

Modern Power Transmission networks are becoming increasingly stressed due to growing demand and restrictions on building new lines. Losing stability is one of the major threat of such a stressed system following a disturbance. Flexible ac transmission system (FACTS) devices are found to be very effective in a transmission network for better utilization of its existing facilities without sacrificing the desired stability margin. The static synchronous compensator (STATCOM) and Static Var Compensator (SVC) are the shunt devices of the flexible AC transmission systems (FACTS) family. When system voltage is low, STATCOM generates reactive power and when system voltage is high it absorbs reactive power whereas the Static Var compensator provides the fast acting dynamic compensation in case of severe faults. In this Paper, the performance of SVC is compared with the performance of STATCOM. Proposed controllers are implemented using MATLAB/SIMULINK. Simulation results indicate that the STATCOM controller installed with two machine systems provides better damping characteristics in rotor angle as compared to two machine system installed with SVC. Thus, transient stability enhancement of the two machine system installed with STATCOM is better than that installed with SVC.

About this research paper

What this paper is about

Modern Power Transmission networks are becoming increasingly stressed due to growing demand and restrictions on building new lines. Losing stability is one of the major threat of such a stressed system following a disturbance. Flexible ac transmission system (FACTS) devices are found to be very effective in a transmission network for better utilization of its existing facilities without sacrificing the desired stability margin. The static synchronous compensator (STATCOM) and Static Var Compensator (SVC) are the shunt devices of the flexible AC transmission systems (FACTS) family. When system voltage is low, STATCOM generates reactive power and when system voltage is high it absorbs reactive power whereas the Static Var compensator provides the fast acting dynamic compensation in case of severe faults. In this Paper, the performance of SVC is compared with the performance of STATCOM. Proposed controllers are implemented using MATLAB/SIMULINK. Simulation results indicate that the STATCOM controller installed with two machine systems provides better damping characteristics in rotor angle as compared to two machine system installed with SVC. Thus, transient stability enhancement of the two machine system installed with STATCOM is better than that installed with SVC.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Modern Power Transmission networks are becoming increasingly stressed due to growing demand and restrictions on building new lines. Losing stability is one of the major threat of such a stressed system following a disturbance. Flexible ac transmission system (FACTS) devices are found to be very effective in a transmission network for better utilization of its existing facilities without sacrificing the desired stability margin. The static synchronous compensator (STATCOM) and Static Var Compensator (SVC) are the shunt devices of the flexible AC transmission systems (FACTS) family. When system voltage is low, STATCOM generates reactive power and when system voltage is high it absorbs reactive power whereas the Static Var compensator provides the fast acting dynamic compensation in case of severe faults. In this Paper, the performance of SVC is compared with the performance of STATCOM. Proposed controllers are implemented using MATLAB/SIMULINK. Simulation results indicate that the STATCOM controller installed with two machine systems provides better damping characteristics in rotor angle as compared to two machine system installed with SVC. Thus, transient stability enhancement of the two machine system installed with STATCOM is better than that installed with SVC.

Key concepts: Static VAR compensator, Electric power system, Control theory (sociology), AC power, MATLAB, Flexible AC transmission system, Transmission system, Transient (computer programming)

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of FACTS Devices for Two Area Power System Stability Enhancement using MATLAB Modelling — Research Paper | ScholarLens