2003DOAJ (DOAJ: Directory of Open Access Journals)Open access

A note on erythrocyte counts in cerebrospinal fluid with the automated hematology analyzer, Technicon H*3

Suphan Soogarun, Viroj Wiwanitkit

Open full text 0 citations

Abstract

Material and Methods: We tested the hematology analyzer, Technicon H*3, which was not designed for CSF analysis. Twenty CSF samples were analyzed. The counts obtained were then compared with the manual microscopic method. Results: Linearity was tested by normal saline solution (NSS). The results of the comparison of both methods used for the determination of total erythrocytes in the CSF exhibited a good correlation (y = 0.836X + 1902.49; r = 0.849, p < 0.001). Conclusion: According to our study, the use of this automated analyzer for cell counting in CSF is probably feasible. The high degree of accuracy and linearity that is offered by the analyzer should prompt us and the manufacturers to remedy the interfering factors as described by improving the algorithms. Once this is done, these analyzers may be very useful for cell counts in CSF.

About this research paper

What this paper is about

Material and Methods: We tested the hematology analyzer, Technicon H*3, which was not designed for CSF analysis. Twenty CSF samples were analyzed. The counts obtained were then compared with the manual microscopic method. Results: Linearity was tested by normal saline solution (NSS). The results of the comparison of both methods used for the determination of total erythrocytes in the CSF exhibited a good correlation (y = 0.836X + 1902.49; r = 0.849, p < 0.001). Conclusion: According to our study, the use of this automated analyzer for cell counting in CSF is probably feasible. The high degree of accuracy and linearity that is offered by the analyzer should prompt us and the manufacturers to remedy the interfering factors as described by improving the algorithms. Once this is done, these analyzers may be very useful for cell counts in CSF.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Material and Methods: We tested the hematology analyzer, Technicon H*3, which was not designed for CSF analysis. Twenty CSF samples were analyzed. The counts obtained were then compared with the manual microscopic method. Results: Linearity was tested by normal saline solution (NSS). The results of the comparison of both methods used for the determination of total erythrocytes in the CSF exhibited a good correlation (y = 0.836X + 1902.49; r = 0.849, p < 0.001). Conclusion: According to our study, the use of this automated analyzer for cell counting in CSF is probably feasible. The high degree of accuracy and linearity that is offered by the analyzer should prompt us and the manufacturers to remedy the interfering factors as described by improving the algorithms. Once this is done, these analyzers may be very useful for cell counts in CSF.

Key concepts: AutoAnalyzer, Hematology analyzer, Hematology, Cerebrospinal fluid, Medicine, Spectrum analyzer, Internal medicine, Leukocyte Counts

Related papers

Back to paper searchBrowse research topicsOriginal source
A note on erythrocyte counts in cerebrospinal fluid with the automated hematology analyzer, Technicon H*3 — Research Paper | ScholarLens