2009•Arrow@dit (Dublin Institute of Technology)Open access

A COMPARISON OF THE AEROBIC ENERGY DEMANDS OF TWO COMMERCIALLY AVAILABLE CYCLE ERGOMETERS IN TRAINED CYCLISTS

Gregory May, Giles David Warrington

Open full text 0 citations

Abstract

The purpose of this study was to compare the energy demands of two cycling ergometers, (Velotron Dynafit Pro and Monark 834E) commonly used in the physiological monitoring of elite athletes. Eight trained male cyclists with a minimum 2 years training and racing experience participated in the study. Each subject completed an exercise trial involving a maximal incremental test. Testing was performed in a random order on either the Velotron or Monark cycle ergometer at the same time of day with no more than 14 days between each testing session. Subjects were requested to maintain their normal training and nutritional practices during the course of the study but to refrain from any intensive training 48 hours prior to each testing session. During the incremental testing significant differences for power output (PO), heart rate (HR), and oxygen uptake (VO2) were found at both at fixed blood lactate (BL) reference points of; 2.5mmol l-1 (REF2.5mM) and at 4mmol.l-1 (REF4mM). Overall the Velotron appeared to provide a more specific measure of cycling performance with significantly lower energy demands at fixed submaximal exercise intensities being observed as well as a significantly greater peak power output and time to exhaustion being attained, which may reflect the specific cycling position adopted. Further research is required to compare the findings of this study with actual cycling performance.

Open-access reader

About this research paper

What this paper is about

The purpose of this study was to compare the energy demands of two cycling ergometers, (Velotron Dynafit Pro and Monark 834E) commonly used in the physiological monitoring of elite athletes. Eight trained male cyclists with a minimum 2 years training and racing experience participated in the study. Each subject completed an exercise trial involving a maximal incremental test. Testing was performed in a random order on either the Velotron or Monark cycle ergometer at the same time of day with no more than 14 days between each testing session. Subjects were requested to maintain their normal training and nutritional practices during the course of the study but to refrain from any intensive training 48 hours prior to each testing session. During the incremental testing significant differences for power output (PO), heart rate (HR), and oxygen uptake (VO2) were found at both at fixed blood lactate (BL) reference points of; 2.5mmol l-1 (REF2.5mM) and at 4mmol.l-1 (REF4mM). Overall the Velotron appeared to provide a more specific measure of cycling performance with significantly lower energy demands at fixed submaximal exercise intensities being observed as well as a significantly greater peak power output and time to exhaustion being attained, which may reflect the specific cycling position adopted. Further research is required to compare the findings of this study with actual cycling performance.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The purpose of this study was to compare the energy demands of two cycling ergometers, (Velotron Dynafit Pro and Monark 834E) commonly used in the physiological monitoring of elite athletes. Eight trained male cyclists with a minimum 2 years training and racing experience participated in the study. Each subject completed an exercise trial involving a maximal incremental test. Testing was performed in a random order on either the Velotron or Monark cycle ergometer at the same time of day with no more than 14 days between each testing session. Subjects were requested to maintain their normal training and nutritional practices during the course of the study but to refrain from any intensive training 48 hours prior to each testing session. During the incremental testing significant differences for power output (PO), heart rate (HR), and oxygen uptake (VO2) were found at both at fixed blood lactate (BL) reference points of; 2.5mmol l-1 (REF2.5mM) and at 4mmol.l-1 (REF4mM). Overall the Velotron appeared to provide a more specific measure of cycling performance with significantly lower energy demands at fixed submaximal exercise intensities being observed as well as a significantly greater peak power output and time to exhaustion being attained, which may reflect the specific cycling position adopted. Further research is required to compare the findings of this study with actual cycling performance.

Key concepts: Cycling, Time trial, VO2 max, Physical therapy, Heart rate, Blood lactate, Cycle ergometer, Aerobic exercise

Related papers

Back to paper searchBrowse research topicsOriginal source
A COMPARISON OF THE AEROBIC ENERGY DEMANDS OF TWO COMMERCIALLY AVAILABLE CYCLE ERGOMETERS IN TRAINED CYCLISTS — Research Paper | ScholarLens