Biological Responses of Isolated Macrophages to Cobalt Metal and Tungsten Carbide‐Cobalt Powders
Dominique Lison, R. Lauwerys
Abstract
Dominique Lison, R. Lauwerys
Abstract
A previous study from this laboratory, using morphological and biochemical (LDH release) parameters, has shown that tungsten carbide-cobalt dust exhibits a greater cytotoxicity toward isolated macrophages than cobalt metal powder alone. The present study extends this comparison by examining additional biological parameters. Glucose uptake and superoxide anion production by isolated macrophages were significantly more depressed by the tungsten carbide-cobalt mixture (WC-Co) than by cobalt alone (Co) while pure tungsten carbide (WC) had no effect or even stimulated the cells. For glucose-6-phosphate dehydrogenase and cell-associated plasminogen activator (PA) activities, no difference between Co and WC-Co dusts was observed. These observations add further evidence to our previous findings regarding the different biological reactivity of cobalt metal alone or mixed with tungsten carbide.
OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A previous study from this laboratory, using morphological and biochemical (LDH release) parameters, has shown that tungsten carbide-cobalt dust exhibits a greater cytotoxicity toward isolated macrophages than cobalt metal powder alone. The present study extends this comparison by examining additional biological parameters. Glucose uptake and superoxide anion production by isolated macrophages were significantly more depressed by the tungsten carbide-cobalt mixture (WC-Co) than by cobalt alone (Co) while pure tungsten carbide (WC) had no effect or even stimulated the cells. For glucose-6-phosphate dehydrogenase and cell-associated plasminogen activator (PA) activities, no difference between Co and WC-Co dusts was observed. These observations add further evidence to our previous findings regarding the different biological reactivity of cobalt metal alone or mixed with tungsten carbide.
Key concepts: Cobalt, Tungsten carbide, Hard metal, Metal, Nuclear chemistry, Tungsten, Superoxide, Materials science