2011•PubMedRequires access

Marginal microleakage of triage sealant under different moisture contamination.

Yawen Peng, Paul C. Stark, Alfred P Rich, Cheen Yau Loo

Open publisher page 7 citations

Abstract

PURPOSE: Glass ionomer sealants (GISs) are promoted in pediatric dentistry for their moisture-friendly properties. This study's purpose was to investigate the marginal leakage of a glass ionomer sealant (Fuji Triage) under different moisture environments. METHODS: Eighty extracted teeth were distributed into 4 groups: (1) control; (2) saliva contamination with 1-second air-thinning; (3) saliva contamination with 10 seconds of air-drying; and (4) saliva contamination with reconditioning. Sealants were placed after contamination. All extracted teeth underwent thermocycling followed by 1% methylene blue dye and distilled water wash. All extracted teeth were then sectioned buccolingually into 3 cross-sections and examined at 60X under a stereomicroscope. Microleakage was assessed using a dye penetration scoring system (score=0-3). Data were analyzed with Kruskal-Wallis and Mann-Whitney tests. RESULTS: The control group showed significantly lower marginal leakage than the other 3 groups (P<.02). There was no statistically significant difference among the 3 contaminated groups (P>.34). CONCLUSIONS: Fuji Triage sealant had the least marginal leakage under a moisture-controlled environment. When saliva was introduced during the application of the material, microleakage significantly increased. When contamination occurred, 1-second air-thinning of the saliva, 10-second air-drying of the saliva, or reconditioning before sealant application did not show a difference in decreasing microleakage.

About this research paper

What this paper is about

PURPOSE: Glass ionomer sealants (GISs) are promoted in pediatric dentistry for their moisture-friendly properties. This study's purpose was to investigate the marginal leakage of a glass ionomer sealant (Fuji Triage) under different moisture environments. METHODS: Eighty extracted teeth were distributed into 4 groups: (1) control; (2) saliva contamination with 1-second air-thinning; (3) saliva contamination with 10 seconds of air-drying; and (4) saliva contamination with reconditioning. Sealants were placed after contamination. All extracted teeth underwent thermocycling followed by 1% methylene blue dye and distilled water wash. All extracted teeth were then sectioned buccolingually into 3 cross-sections and examined at 60X under a stereomicroscope. Microleakage was assessed using a dye penetration scoring system (score=0-3). Data were analyzed with Kruskal-Wallis and Mann-Whitney tests. RESULTS: The control group showed significantly lower marginal leakage than the other 3 groups (P<.02). There was no statistically significant difference among the 3 contaminated groups (P>.34). CONCLUSIONS: Fuji Triage sealant had the least marginal leakage under a moisture-controlled environment. When saliva was introduced during the application of the material, microleakage significantly increased. When contamination occurred, 1-second air-thinning of the saliva, 10-second air-drying of the saliva, or reconditioning before sealant application did not show a difference in decreasing microleakage.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: Glass ionomer sealants (GISs) are promoted in pediatric dentistry for their moisture-friendly properties. This study's purpose was to investigate the marginal leakage of a glass ionomer sealant (Fuji Triage) under different moisture environments. METHODS: Eighty extracted teeth were distributed into 4 groups: (1) control; (2) saliva contamination with 1-second air-thinning; (3) saliva contamination with 10 seconds of air-drying; and (4) saliva contamination with reconditioning. Sealants were placed after contamination. All extracted teeth underwent thermocycling followed by 1% methylene blue dye and distilled water wash. All extracted teeth were then sectioned buccolingually into 3 cross-sections and examined at 60X under a stereomicroscope. Microleakage was assessed using a dye penetration scoring system (score=0-3). Data were analyzed with Kruskal-Wallis and Mann-Whitney tests. RESULTS: The control group showed significantly lower marginal leakage than the other 3 groups (P<.02). There was no statistically significant difference among the 3 contaminated groups (P>.34). CONCLUSIONS: Fuji Triage sealant had the least marginal leakage under a moisture-controlled environment. When saliva was introduced during the application of the material, microleakage significantly increased. When contamination occurred, 1-second air-thinning of the saliva, 10-second air-drying of the saliva, or reconditioning before sealant application did not show a difference in decreasing microleakage.

Key concepts: Sealant, Dentistry, Saliva, Medicine, Glass ionomer cement, Contamination, Moisture, Varnish

Related papers

Back to paper searchBrowse research topicsOriginal source
Marginal microleakage of triage sealant under different moisture contamination. — Research Paper | ScholarLens