1998Nuclear TechnologyRequires access

Heat Transfer Analysis of the Passive Residual Heat Removal System in ROSA/AP600 Experiments

Taisuke Yonomoto, Yutaka Kukita, Richard R. Schultz

Open publisher page 50 citations

Abstract

The passive residual heat removal (PRHR) system in the Westinghouse AP600 advanced passive reactor design is a natural-circulation-driven heat exchanger cooled by the water in the in-containment refueling water storage tank (IRWST). During the experiments, which simulated small-break loss-of-coolant accidents in the AP600 reactor using the ROSA-V Large-Scale Test Facility (LSTF), the PRHR system heat removal rates well exceeded the core decay power soon after the actuation of the PRHR. This resulted in continuous cooldown and depressurization of the primary side. The PRHR heat transfer performance in these experiments was analyzed by applying heat transfer correlations available in literature to the PRHR heat exchanger tube bundle. Also, the three-dimensional natural circulation in the IRWST was simulated numerically using the FLUENT code. The total heat transfer rate of the PRHR was predicted within 5% of the measured value. The fluid temperature distribution in the IRWST was also predicted well except that the elevation of the thermally stratified region was underpredicted. The calculated flow pattern in the IRWST suggests that the atypical IRWST geometry in the LSTF may have affected the PRHR heat transfer performance during the experiments only a little.

About this research paper

What this paper is about

The passive residual heat removal (PRHR) system in the Westinghouse AP600 advanced passive reactor design is a natural-circulation-driven heat exchanger cooled by the water in the in-containment refueling water storage tank (IRWST). During the experiments, which simulated small-break loss-of-coolant accidents in the AP600 reactor using the ROSA-V Large-Scale Test Facility (LSTF), the PRHR system heat removal rates well exceeded the core decay power soon after the actuation of the PRHR. This resulted in continuous cooldown and depressurization of the primary side. The PRHR heat transfer performance in these experiments was analyzed by applying heat transfer correlations available in literature to the PRHR heat exchanger tube bundle. Also, the three-dimensional natural circulation in the IRWST was simulated numerically using the FLUENT code. The total heat transfer rate of the PRHR was predicted within 5% of the measured value. The fluid temperature distribution in the IRWST was also predicted well except that the elevation of the thermally stratified region was underpredicted. The calculated flow pattern in the IRWST suggests that the atypical IRWST geometry in the LSTF may have affected the PRHR heat transfer performance during the experiments only a little.

Why it matters

OpenAlex reports 50 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The passive residual heat removal (PRHR) system in the Westinghouse AP600 advanced passive reactor design is a natural-circulation-driven heat exchanger cooled by the water in the in-containment refueling water storage tank (IRWST). During the experiments, which simulated small-break loss-of-coolant accidents in the AP600 reactor using the ROSA-V Large-Scale Test Facility (LSTF), the PRHR system heat removal rates well exceeded the core decay power soon after the actuation of the PRHR. This resulted in continuous cooldown and depressurization of the primary side. The PRHR heat transfer performance in these experiments was analyzed by applying heat transfer correlations available in literature to the PRHR heat exchanger tube bundle. Also, the three-dimensional natural circulation in the IRWST was simulated numerically using the FLUENT code. The total heat transfer rate of the PRHR was predicted within 5% of the measured value. The fluid temperature distribution in the IRWST was also predicted well except that the elevation of the thermally stratified region was underpredicted. The calculated flow pattern in the IRWST suggests that the atypical IRWST geometry in the LSTF may have affected the PRHR heat transfer performance during the experiments only a little.

Key concepts: Natural circulation, Heat exchanger, Nuclear engineering, Heat transfer, Decay heat, Coolant, Environmental science, Plate heat exchanger

Related papers

Back to paper searchBrowse research topicsOriginal source
Heat Transfer Analysis of the Passive Residual Heat Removal System in ROSA/AP600 Experiments — Research Paper | ScholarLens