A short review of diagnosis and compression therapy of chronic venous insufficiency.
Nada Kecelj Leskovec, M. Pavlovič, Tomaž Lunder
Abstract
Nada Kecelj Leskovec, M. Pavlovič, Tomaž Lunder
Abstract
INTRODUCTION: Chronic venous insufficiency (CVI) is a venous disorder in the lower extremities associated with changes in the skin and subcutaneous tissue. Treatment with short-stretch compression bandages is highly recommended for advanced stages of CVI. METHODS: The compression systems Rosidal Sys, Porelast, Coban, and Proguide were evaluated in 4 groups of mobile and active patients (n = 18) with CVI stage II or III. Sub-bandage pressures at point B1 were measured in the upright and supine positions 30 min and 12 h after the bandage was applied. Average pressures and values of the static stiffness index (SSI) were calculated for each group. RESULTS: The Porelast, Rosidal Sys and Coban systems had SSI values in excess of 10 mmHg, 30 min and 12 h after application. The corresponding values for Proguide were below 10 mmHg. CONCLUSION: Porelast, Rosidal Sys and Coban are very stiff systems, whereas Proguide is more similar to long-stretch compression bandages with a lower degree of stiffness.
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
INTRODUCTION: Chronic venous insufficiency (CVI) is a venous disorder in the lower extremities associated with changes in the skin and subcutaneous tissue. Treatment with short-stretch compression bandages is highly recommended for advanced stages of CVI. METHODS: The compression systems Rosidal Sys, Porelast, Coban, and Proguide were evaluated in 4 groups of mobile and active patients (n = 18) with CVI stage II or III. Sub-bandage pressures at point B1 were measured in the upright and supine positions 30 min and 12 h after the bandage was applied. Average pressures and values of the static stiffness index (SSI) were calculated for each group. RESULTS: The Porelast, Rosidal Sys and Coban systems had SSI values in excess of 10 mmHg, 30 min and 12 h after application. The corresponding values for Proguide were below 10 mmHg. CONCLUSION: Porelast, Rosidal Sys and Coban are very stiff systems, whereas Proguide is more similar to long-stretch compression bandages with a lower degree of stiffness.
Key concepts: Chronic venous insufficiency, Supine position, Bandage, Compression therapy, Compression Bandage, Medicine, Surgery, Compression (physics)