Effect of openings of shear wall in high rise buildings
V. P. Kulkarni, Swapnil B. Cholekar, Hemant L. Sonawadekar
Abstract
V. P. Kulkarni, Swapnil B. Cholekar, Hemant L. Sonawadekar
Abstract
Abstract: Buildings with cast-in-situ reinforced concrete shear walls are widespread in many earthquake-prone countries and regions, such as India. Reinforced Concrete buildings often have vertical plate-like RC walls called Shear Walls. Shear walls are vertical walls that are designed to receive lateral forces from diaphragms and transmit them to the ground. The buildings with shear walls improve the lateral load resistance. The shear walls with openings are provided for functional requirement. Therefore, in the present work, an analytical parametric study is done for high rise buildings with the shear walls with and without openings for different shapes such as, centrally core (Box type) and at four opposite corners (L-Shape). Dynamic analysis is carried out using STAAD Pro software. The Load combinations are considered as per IS 1893 (Part 1): 2002. The results in terms of lateral displacements and design base shear in shear walls with openings and without openings are compared for the different building models considered in this investigation. It is observed that L-type shear wall shows better performance than Box type shear wall. As number of openings increases base shear decreases and displacement increases with increase in number of openings. Key words: Dynamic analysis; shear wall; base shear; openings; displacement; staad pro software. 1.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract: Buildings with cast-in-situ reinforced concrete shear walls are widespread in many earthquake-prone countries and regions, such as India. Reinforced Concrete buildings often have vertical plate-like RC walls called Shear Walls. Shear walls are vertical walls that are designed to receive lateral forces from diaphragms and transmit them to the ground. The buildings with shear walls improve the lateral load resistance. The shear walls with openings are provided for functional requirement. Therefore, in the present work, an analytical parametric study is done for high rise buildings with the shear walls with and without openings for different shapes such as, centrally core (Box type) and at four opposite corners (L-Shape). Dynamic analysis is carried out using STAAD Pro software. The Load combinations are considered as per IS 1893 (Part 1): 2002. The results in terms of lateral displacements and design base shear in shear walls with openings and without openings are compared for the different building models considered in this investigation. It is observed that L-type shear wall shows better performance than Box type shear wall. As number of openings increases base shear decreases and displacement increases with increase in number of openings. Key words: Dynamic analysis; shear wall; base shear; openings; displacement; staad pro software. 1.
Key concepts: Shear wall, Shear (geology), Structural engineering, Reinforced concrete, Geotechnical engineering, Geology, Shear force, Structural load