Anticipated transient without SCRAM experiments at LOFT
W.H. Grush, Edwin A. Harvego, Yasuo Koizumi, D.J. Varacalle
Abstract
W.H. Grush, Edwin A. Harvego, Yasuo Koizumi, D.J. Varacalle
Abstract
This paper discusses the experimental results for two anticipated transients without scram (ATWS) experiments, and compares computer code predictions with the experimental data. Experiment L9-3 simulated an ATWS in a commercial pressurized water reactor (PWR) initiated by a complete loss of feedwater and Experiment L9-4 simulated a loss-of-offsite-power-initiated (loss of feedwater and trip of the primary coolant pumps) ATWS. The LOFT facility is uniquely suited for ATWS experiments because it is a volumetrically scaled (1/44) experimental PWR designed to simulate the major components and system responses of larger commercial PWRs during both hypothesized loss-of-coolant accidents and anticipated transients. In both of the examined experiments, the primary system transient behavior was dominated by the interactions between the steam generator primary-to-secondary heat removal, the reactor kinetics, and the relief valve actuation. It is demonstrated that the discussed ATWS events can be controlled by properly sized automatic safety systems.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This paper discusses the experimental results for two anticipated transients without scram (ATWS) experiments, and compares computer code predictions with the experimental data. Experiment L9-3 simulated an ATWS in a commercial pressurized water reactor (PWR) initiated by a complete loss of feedwater and Experiment L9-4 simulated a loss-of-offsite-power-initiated (loss of feedwater and trip of the primary coolant pumps) ATWS. The LOFT facility is uniquely suited for ATWS experiments because it is a volumetrically scaled (1/44) experimental PWR designed to simulate the major components and system responses of larger commercial PWRs during both hypothesized loss-of-coolant accidents and anticipated transients. In both of the examined experiments, the primary system transient behavior was dominated by the interactions between the steam generator primary-to-secondary heat removal, the reactor kinetics, and the relief valve actuation. It is demonstrated that the discussed ATWS events can be controlled by properly sized automatic safety systems.
Key concepts: Scram, Boiler feedwater, Nuclear engineering, Coolant, Transient (computer programming), Safety valve, Boiler (water heating), Environmental science