2013Asian journal of biomedical and pharmaceutical sciencesRequires access

Development and validation of UV Spectrometric Method for the Determination of Cefixime trihydrate in Bulk and Pharmaceutical Formulation

Md. Ahasan Ullah Nayon, Jeb-Un Nesa, Md Nasir Uddin, Md. Shah Amran, Umme Bushra

Open publisher page 15 citations

Abstract

The present study was undertaken to develop and validate a simple, accurate, precise, reproducible and cost effective UV-Visible spectrophotometric method for the estimation of cefixime trihydrate in bulk and pharmaceutical formulation. The solvent used throughout the experiment was the mixer of methanol and water. Absorption maximum (λmax) of the drug was found to be 287 nm. The quantitative determination of the drug was carried out at 287 nm and Beer’s law was obeyed in the range of 2-20μg/mL. The method was shown linear in the mentioned concentrations having line equation y = 0.025x + 0.078 with correlation coefficient of 0.999. The recovery values for cefixime trihydrate ranged from 99.57% - 100.86%. The relative standard deviation of six replicates of assay was less than 2%. The percent relative standard deviation (RSD%) of interday precision range was 0.059 – 0.546 % and intraday precision range was 0.102 – 0.299%. The limit of detection and limit of quantification was 0.053 μg/mL and 0.159 μg/mL. The percent relative standard deviation of robustness and ruggedness of the method was 0.258 - 0.365%. Hence, proposed method was precise, accurate and cost effective. This method could be applicable for quantitative determination of the bulk drug as well as dosage formulation.

About this research paper

What this paper is about

The present study was undertaken to develop and validate a simple, accurate, precise, reproducible and cost effective UV-Visible spectrophotometric method for the estimation of cefixime trihydrate in bulk and pharmaceutical formulation. The solvent used throughout the experiment was the mixer of methanol and water. Absorption maximum (λmax) of the drug was found to be 287 nm. The quantitative determination of the drug was carried out at 287 nm and Beer’s law was obeyed in the range of 2-20μg/mL. The method was shown linear in the mentioned concentrations having line equation y = 0.025x + 0.078 with correlation coefficient of 0.999. The recovery values for cefixime trihydrate ranged from 99.57% - 100.86%. The relative standard deviation of six replicates of assay was less than 2%. The percent relative standard deviation (RSD%) of interday precision range was 0.059 – 0.546 % and intraday precision range was 0.102 – 0.299%. The limit of detection and limit of quantification was 0.053 μg/mL and 0.159 μg/mL. The percent relative standard deviation of robustness and ruggedness of the method was 0.258 - 0.365%. Hence, proposed method was precise, accurate and cost effective. This method could be applicable for quantitative determination of the bulk drug as well as dosage formulation.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The present study was undertaken to develop and validate a simple, accurate, precise, reproducible and cost effective UV-Visible spectrophotometric method for the estimation of cefixime trihydrate in bulk and pharmaceutical formulation. The solvent used throughout the experiment was the mixer of methanol and water. Absorption maximum (λmax) of the drug was found to be 287 nm. The quantitative determination of the drug was carried out at 287 nm and Beer’s law was obeyed in the range of 2-20μg/mL. The method was shown linear in the mentioned concentrations having line equation y = 0.025x + 0.078 with correlation coefficient of 0.999. The recovery values for cefixime trihydrate ranged from 99.57% - 100.86%. The relative standard deviation of six replicates of assay was less than 2%. The percent relative standard deviation (RSD%) of interday precision range was 0.059 – 0.546 % and intraday precision range was 0.102 – 0.299%. The limit of detection and limit of quantification was 0.053 μg/mL and 0.159 μg/mL. The percent relative standard deviation of robustness and ruggedness of the method was 0.258 - 0.365%. Hence, proposed method was precise, accurate and cost effective. This method could be applicable for quantitative determination of the bulk drug as well as dosage formulation.

Key concepts: Relative standard deviation, Detection limit, Cefixime, Pharmaceutical formulation, Standard deviation, Dosage form, Chromatography, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Development and validation of UV Spectrometric Method for the Determination of Cefixime trihydrate in Bulk and Pharmaceutical Formulation — Research Paper | ScholarLens