2011Hydrological ProcessesRequires access

Multivariate approaches optimize locations of groundwater pumping facilities for different hydrogeological scales

Hsien‐Tsung Lin, Yih‐Chi Tan, Chu‐Hui Chen, W. Sabrina Lin, Chen‐Wuing Liu

Open publisher page 3 citations

Abstract

Abstract A number of optimization approaches regarding the design location of groundwater pumping facilities in heterogeneous porous media have elicited little discussion. However, the location of groundwater pumping facilities is an important factor because it affects water resource usage. This study applies two optimization approaches to estimate the best recharge zone and suitable locations of the pumping facilities in southwestern Taiwan for different hydrogeological scales. First, for the regional scale, this study employs numerical modelling, MODFLOW‐96, to simulate groundwater direction and the optimal recharge zone in the study area. Based on the model's calibration and verification results, this study preliminarily utilizes the simulated spatial direction of groundwater and compares the safe yield for each well group in order to determine the best recharge zone. Additionally, for the local scale, the micro‐hydrogeological characteristics are considered before determining the design locations of the pumping facilities. According to drawdown record data from six observation wells derived from pumping tests at the best recharge area, this study further utilizes the modified artificial neural network approach to improve the accuracy of the estimation parameters as well as to analyse the direction and anisotropy of the hydraulic conductivities of an equivalent homogeneous aquifer. The results suggested that the best locations for the pumping facilities are along the more permeable major direction. Copyright © 2011 John Wiley & Sons, Ltd.

About this research paper

What this paper is about

Abstract A number of optimization approaches regarding the design location of groundwater pumping facilities in heterogeneous porous media have elicited little discussion. However, the location of groundwater pumping facilities is an important factor because it affects water resource usage. This study applies two optimization approaches to estimate the best recharge zone and suitable locations of the pumping facilities in southwestern Taiwan for different hydrogeological scales. First, for the regional scale, this study employs numerical modelling, MODFLOW‐96, to simulate groundwater direction and the optimal recharge zone in the study area. Based on the model's calibration and verification results, this study preliminarily utilizes the simulated spatial direction of groundwater and compares the safe yield for each well group in order to determine the best recharge zone. Additionally, for the local scale, the micro‐hydrogeological characteristics are considered before determining the design locations of the pumping facilities. According to drawdown record data from six observation wells derived from pumping tests at the best recharge area, this study further utilizes the modified artificial neural network approach to improve the accuracy of the estimation parameters as well as to analyse the direction and anisotropy of the hydraulic conductivities of an equivalent homogeneous aquifer. The results suggested that the best locations for the pumping facilities are along the more permeable major direction. Copyright © 2011 John Wiley & Sons, Ltd.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract A number of optimization approaches regarding the design location of groundwater pumping facilities in heterogeneous porous media have elicited little discussion. However, the location of groundwater pumping facilities is an important factor because it affects water resource usage. This study applies two optimization approaches to estimate the best recharge zone and suitable locations of the pumping facilities in southwestern Taiwan for different hydrogeological scales. First, for the regional scale, this study employs numerical modelling, MODFLOW‐96, to simulate groundwater direction and the optimal recharge zone in the study area. Based on the model's calibration and verification results, this study preliminarily utilizes the simulated spatial direction of groundwater and compares the safe yield for each well group in order to determine the best recharge zone. Additionally, for the local scale, the micro‐hydrogeological characteristics are considered before determining the design locations of the pumping facilities. According to drawdown record data from six observation wells derived from pumping tests at the best recharge area, this study further utilizes the modified artificial neural network approach to improve the accuracy of the estimation parameters as well as to analyse the direction and anisotropy of the hydraulic conductivities of an equivalent homogeneous aquifer. The results suggested that the best locations for the pumping facilities are along the more permeable major direction. Copyright © 2011 John Wiley & Sons, Ltd.

Key concepts: Groundwater recharge, Hydrogeology, MODFLOW, Aquifer, Groundwater, Aquifer properties, Drawdown (hydrology), Hydrology (agriculture)

Related papers

Back to paper searchBrowse research topicsOriginal source
Multivariate approaches optimize locations of groundwater pumping facilities for different hydrogeological scales — Research Paper | ScholarLens