Influence of analgesic supplementation on the target propofol concentrations for anaesthesia with ‘Diprifusor’ TCI
Frederique S. Servin, Florence Marchand-Maillet, Jean-Marie Desmonts
Abstract
Open-access reader
Frederique S. Servin, Florence Marchand-Maillet, Jean-Marie Desmonts
Abstract
Open-access reader
Forty healthy patients undergoing orthopaedic surgery were randomly allocated to receive an initial blood propofol target concentration of either 4 micrograms.ml-1 or 6 micrograms.ml-1 for induction of anaesthesia with a 'Diprifusor' target controlled infusion system for propofol, and analgesic supplementation with either nitrous oxide 67% in oxygen or alfentanil 15-20 micrograms.kg-1.h-1. Anaesthesia was induced within 3 min in 80% and 95% of patients with propofol target concentrations of 4 micrograms.ml-1 and 6 micrograms.ml-1, respectively. The frequency of discomfort on infusion was similar for both target concentrations. During maintenance, supplementary doses of alfentanil were required to provide adequate surgical conditions in approximately half of the patients receiving nitrous oxide. There was no statistically significant difference between the target concentration [mean (SD)] of propofol for total intravenous anaesthesia [5.1 (2.0) micrograms.ml-1] compared with a technique using nitrous oxide [4.6 (1.2) micrograms.ml-1] supplemented as needed with small doses of alfentanil.
OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Forty healthy patients undergoing orthopaedic surgery were randomly allocated to receive an initial blood propofol target concentration of either 4 micrograms.ml-1 or 6 micrograms.ml-1 for induction of anaesthesia with a 'Diprifusor' target controlled infusion system for propofol, and analgesic supplementation with either nitrous oxide 67% in oxygen or alfentanil 15-20 micrograms.kg-1.h-1. Anaesthesia was induced within 3 min in 80% and 95% of patients with propofol target concentrations of 4 micrograms.ml-1 and 6 micrograms.ml-1, respectively. The frequency of discomfort on infusion was similar for both target concentrations. During maintenance, supplementary doses of alfentanil were required to provide adequate surgical conditions in approximately half of the patients receiving nitrous oxide. There was no statistically significant difference between the target concentration [mean (SD)] of propofol for total intravenous anaesthesia [5.1 (2.0) micrograms.ml-1] compared with a technique using nitrous oxide [4.6 (1.2) micrograms.ml-1] supplemented as needed with small doses of alfentanil.
Key concepts: Alfentanil, Propofol, Medicine, Nitrous oxide, Anesthesia, Analgesic, Target controlled infusion, General anaesthesia