2007•FEBS JournalOpen access

Functional importance of charged residues within the putative intracellular loops in pH regulation by Na+/ H+ exchanger NHE1

Takashi Hisamitsu, Keiji Yamada, Tomoe Y. Nakamura, Shigeo Wakabayashi

Open full text 14 citations

Abstract

The plasma membrane Na+/H+ exchanger 1 is activated in response to various extrinsic factors, and this process is regulated by an intracellular pH-sensing mechanism. To identify the candidate residues responsible for intracellular pH regulation, we analyzed the functional properties of engineered Na+/H+ exchanger 1 mutants with charge-reversal mutations of charged residues located in the intracellular loops. Na+/H+ exchanger 1 mutants with mutations at 11 positions were well expressed in the plasma membrane, but that with E247R was not, suggesting that Glu247 is important for the functional expression of Na+/H+ exchanger 1. Charge-reversal mutations of Glu131 (E131R, E131K) and Arg327 (R327E) resulted in a shift in the intracellular pH dependence of the exchange activity measured by 22Na+ uptake to the acidic side, and it abolished the response to growth factors and a hyperosmotic medium; however, mutations of Asp448 (D448R) and Arg500 (R500E) slightly shifted it to the alkaline side. In E131R, in addition to the change in intracellular pH dependence, the affinities for extracellular Na+, Li+ and the inhibitor 5-(N-ethyl-N-isopropyl)amiloride significantly increased. Furthermore, charge-conserved mutation of E131 (E131D) was found to have no effect, whereas charge neutralization (E131Q) resulted in a slight acidic shift of exchange. These results support the view that the multiple charged residues identified in this study, along with several basic residues reported previously, participate in the regulation of the intracellular pH sensing of Na+/H+ exchanger 1. In addition, Glu131 may also be important for cation transport.

Open-access reader

About this research paper

What this paper is about

The plasma membrane Na+/H+ exchanger 1 is activated in response to various extrinsic factors, and this process is regulated by an intracellular pH-sensing mechanism. To identify the candidate residues responsible for intracellular pH regulation, we analyzed the functional properties of engineered Na+/H+ exchanger 1 mutants with charge-reversal mutations of charged residues located in the intracellular loops. Na+/H+ exchanger 1 mutants with mutations at 11 positions were well expressed in the plasma membrane, but that with E247R was not, suggesting that Glu247 is important for the functional expression of Na+/H+ exchanger 1. Charge-reversal mutations of Glu131 (E131R, E131K) and Arg327 (R327E) resulted in a shift in the intracellular pH dependence of the exchange activity measured by 22Na+ uptake to the acidic side, and it abolished the response to growth factors and a hyperosmotic medium; however, mutations of Asp448 (D448R) and Arg500 (R500E) slightly shifted it to the alkaline side. In E131R, in addition to the change in intracellular pH dependence, the affinities for extracellular Na+, Li+ and the inhibitor 5-(N-ethyl-N-isopropyl)amiloride significantly increased. Furthermore, charge-conserved mutation of E131 (E131D) was found to have no effect, whereas charge neutralization (E131Q) resulted in a slight acidic shift of exchange. These results support the view that the multiple charged residues identified in this study, along with several basic residues reported previously, participate in the regulation of the intracellular pH sensing of Na+/H+ exchanger 1. In addition, Glu131 may also be important for cation transport.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The plasma membrane Na+/H+ exchanger 1 is activated in response to various extrinsic factors, and this process is regulated by an intracellular pH-sensing mechanism. To identify the candidate residues responsible for intracellular pH regulation, we analyzed the functional properties of engineered Na+/H+ exchanger 1 mutants with charge-reversal mutations of charged residues located in the intracellular loops. Na+/H+ exchanger 1 mutants with mutations at 11 positions were well expressed in the plasma membrane, but that with E247R was not, suggesting that Glu247 is important for the functional expression of Na+/H+ exchanger 1. Charge-reversal mutations of Glu131 (E131R, E131K) and Arg327 (R327E) resulted in a shift in the intracellular pH dependence of the exchange activity measured by 22Na+ uptake to the acidic side, and it abolished the response to growth factors and a hyperosmotic medium; however, mutations of Asp448 (D448R) and Arg500 (R500E) slightly shifted it to the alkaline side. In E131R, in addition to the change in intracellular pH dependence, the affinities for extracellular Na+, Li+ and the inhibitor 5-(N-ethyl-N-isopropyl)amiloride significantly increased. Furthermore, charge-conserved mutation of E131 (E131D) was found to have no effect, whereas charge neutralization (E131Q) resulted in a slight acidic shift of exchange. These results support the view that the multiple charged residues identified in this study, along with several basic residues reported previously, participate in the regulation of the intracellular pH sensing of Na+/H+ exchanger 1. In addition, Glu131 may also be important for cation transport.

Key concepts: Intracellular pH, Intracellular, Extracellular, Chemistry, Mutant, Sodium–hydrogen antiporter, Amiloride, Biophysics

Related papers

Back to paper searchBrowse research topicsOriginal source
Functional importance of charged residues within the putative intracellular loops in pH regulation by Na+/ H+ exchanger NHE1 — Research Paper | ScholarLens