1987•Southern Medical JournalRequires access

Changes in End Tidal CO2 and Arterial Blood Gas Levels After Release of Tourniquet

ASHOKKUMAR J. PATEL, Chang-Shik Choi, JOSEPH G. GIUFFRIDA

Open publisher page 34 citations

Abstract

We studied nine healthy adult patients having orthopedic surgical procedures requiring the use of a tourniquet under general anesthesia with controlled mechanical ventilation to determine changes in end tidal CO2 (EtCO2) and arterial blood gas values after tourniquet deflation. After deflation of the tourniquet, EtCO2 and PaCO2 increased maximally within one minute; EtCO2 returned to baseline at a mean time of 13 minutes 7 seconds +/- 5 minutes 17 seconds, while PaCO2 was still above baseline when the study was terminated. The pH level decreased significantly, with the maximal fall occurring within four minutes; it remained below baseline when the study was terminated. The PaO2 level decreased and the bicarbonate level increased, though neither change was statistically significant. After tourniquet release, hyperventilation may be indicated to facilitate the return of PaCO2 and pH levels to baseline; in patients whose acid-base status is compromised by preexisting disease, PaCO2 and pH should be monitored closely. The PaCO2 level could be predicted by monitoring the EtCO2 level.

About this research paper

What this paper is about

We studied nine healthy adult patients having orthopedic surgical procedures requiring the use of a tourniquet under general anesthesia with controlled mechanical ventilation to determine changes in end tidal CO2 (EtCO2) and arterial blood gas values after tourniquet deflation. After deflation of the tourniquet, EtCO2 and PaCO2 increased maximally within one minute; EtCO2 returned to baseline at a mean time of 13 minutes 7 seconds +/- 5 minutes 17 seconds, while PaCO2 was still above baseline when the study was terminated. The pH level decreased significantly, with the maximal fall occurring within four minutes; it remained below baseline when the study was terminated. The PaO2 level decreased and the bicarbonate level increased, though neither change was statistically significant. After tourniquet release, hyperventilation may be indicated to facilitate the return of PaCO2 and pH levels to baseline; in patients whose acid-base status is compromised by preexisting disease, PaCO2 and pH should be monitored closely. The PaCO2 level could be predicted by monitoring the EtCO2 level.

Why it matters

OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We studied nine healthy adult patients having orthopedic surgical procedures requiring the use of a tourniquet under general anesthesia with controlled mechanical ventilation to determine changes in end tidal CO2 (EtCO2) and arterial blood gas values after tourniquet deflation. After deflation of the tourniquet, EtCO2 and PaCO2 increased maximally within one minute; EtCO2 returned to baseline at a mean time of 13 minutes 7 seconds +/- 5 minutes 17 seconds, while PaCO2 was still above baseline when the study was terminated. The pH level decreased significantly, with the maximal fall occurring within four minutes; it remained below baseline when the study was terminated. The PaO2 level decreased and the bicarbonate level increased, though neither change was statistically significant. After tourniquet release, hyperventilation may be indicated to facilitate the return of PaCO2 and pH levels to baseline; in patients whose acid-base status is compromised by preexisting disease, PaCO2 and pH should be monitored closely. The PaCO2 level could be predicted by monitoring the EtCO2 level.

Key concepts: Medicine, Tourniquet, Hyperventilation, Anesthesia, Arterial blood, Ventilation (architecture), Engineering, Mechanical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Changes in End Tidal CO2 and Arterial Blood Gas Levels After Release of Tourniquet — Research Paper | ScholarLens