1973Journal of the Structural DivisionRequires access

Fire Resistance of Unprotected Steel Columns

W. W. Stanzak, T. T. Lie

Open publisher page 5 citations

Abstract

Fire resistance of unprotected steel columns is examined by standard fire test and numerical analyses based on a 1,000 D F (538 D C) critical temperature for failure. It is shown that fire resistance time varies with the shape factor of column weight divided by the heated perimeter, and two simple equations for calculating the fire resistance times of unprotected steel columns are established. A practical example shows that large columns used in high-rise buildings can have fire resistance times of up to one hr. The more conservative of the two equations is recommended for use in building standards.

About this research paper

What this paper is about

Fire resistance of unprotected steel columns is examined by standard fire test and numerical analyses based on a 1,000 D F (538 D C) critical temperature for failure. It is shown that fire resistance time varies with the shape factor of column weight divided by the heated perimeter, and two simple equations for calculating the fire resistance times of unprotected steel columns are established. A practical example shows that large columns used in high-rise buildings can have fire resistance times of up to one hr. The more conservative of the two equations is recommended for use in building standards.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fire resistance of unprotected steel columns is examined by standard fire test and numerical analyses based on a 1,000 D F (538 D C) critical temperature for failure. It is shown that fire resistance time varies with the shape factor of column weight divided by the heated perimeter, and two simple equations for calculating the fire resistance times of unprotected steel columns are established. A practical example shows that large columns used in high-rise buildings can have fire resistance times of up to one hr. The more conservative of the two equations is recommended for use in building standards.

Key concepts: Fire resistance, Column (typography), Fire protection, Structural engineering, Forensic engineering, Materials science, Engineering, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Fire Resistance of Unprotected Steel Columns — Research Paper | ScholarLens