2002SAE technical papers on CD-ROM/SAE technical paper seriesRequires access

Comparison of Hybrid III, Thor-α and PMHS Response in Frontal Sled Tests

Philippe Vézin, Karine Bruyère-Garnier, François Bermond, Jean Pierre Verriest

Open publisher page 35 citations

Abstract

Two series of nine frontal sled tests were conducted to evaluate the behavior of the Hybrid III and Thor-alpha dummies. The first series was conducted at 50 kph with airbag and 4 kN force-limited shoulder belt and the second series at 30 kph and only a 4 kN force-limited shoulder belt. In each series, three replicate tests were conducted with each dummy and compared with three PMHS. The data provided by the same instrumentation located at the same position were compared to assess the biofidelity of both dummies. The results were mass scaled in order to account for the differences between the anthropometry of the cadaver. The good test-to-test repeatability for each dummy permitted to compare the mean value of each recorded parameter. Based on the cadaver response, the results show that the Thor-alpha provides responses that are more similar to those of PMHS than the Hybrid III. The flexible joints in the thoracic spine, the sternum design and the more humanlike ribcage give more similar accelerations than the Hybrid III as compared to those of the PMHS. Nevertheless, some parts have to be improved in order to better follow the behavior of the human subject. The head-neck complex, the chest, the shoulder and the pelvis of the Thor-alpha have a more humanlike behavior but some differences remain. The distribution of the deceleration between the components is sometimes different compared to those of the cadaver, even if the resultants are similar. The dummies and most particularly the Hybrid III are less sensitive to the change in restraint systems and tests conditions than a cadaver.

About this research paper

What this paper is about

Two series of nine frontal sled tests were conducted to evaluate the behavior of the Hybrid III and Thor-alpha dummies. The first series was conducted at 50 kph with airbag and 4 kN force-limited shoulder belt and the second series at 30 kph and only a 4 kN force-limited shoulder belt. In each series, three replicate tests were conducted with each dummy and compared with three PMHS. The data provided by the same instrumentation located at the same position were compared to assess the biofidelity of both dummies. The results were mass scaled in order to account for the differences between the anthropometry of the cadaver. The good test-to-test repeatability for each dummy permitted to compare the mean value of each recorded parameter. Based on the cadaver response, the results show that the Thor-alpha provides responses that are more similar to those of PMHS than the Hybrid III. The flexible joints in the thoracic spine, the sternum design and the more humanlike ribcage give more similar accelerations than the Hybrid III as compared to those of the PMHS. Nevertheless, some parts have to be improved in order to better follow the behavior of the human subject. The head-neck complex, the chest, the shoulder and the pelvis of the Thor-alpha have a more humanlike behavior but some differences remain. The distribution of the deceleration between the components is sometimes different compared to those of the cadaver, even if the resultants are similar. The dummies and most particularly the Hybrid III are less sensitive to the change in restraint systems and tests conditions than a cadaver.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Two series of nine frontal sled tests were conducted to evaluate the behavior of the Hybrid III and Thor-alpha dummies. The first series was conducted at 50 kph with airbag and 4 kN force-limited shoulder belt and the second series at 30 kph and only a 4 kN force-limited shoulder belt. In each series, three replicate tests were conducted with each dummy and compared with three PMHS. The data provided by the same instrumentation located at the same position were compared to assess the biofidelity of both dummies. The results were mass scaled in order to account for the differences between the anthropometry of the cadaver. The good test-to-test repeatability for each dummy permitted to compare the mean value of each recorded parameter. Based on the cadaver response, the results show that the Thor-alpha provides responses that are more similar to those of PMHS than the Hybrid III. The flexible joints in the thoracic spine, the sternum design and the more humanlike ribcage give more similar accelerations than the Hybrid III as compared to those of the PMHS. Nevertheless, some parts have to be improved in order to better follow the behavior of the human subject. The head-neck complex, the chest, the shoulder and the pelvis of the Thor-alpha have a more humanlike behavior but some differences remain. The distribution of the deceleration between the components is sometimes different compared to those of the cadaver, even if the resultants are similar. The dummies and most particularly the Hybrid III are less sensitive to the change in restraint systems and tests conditions than a cadaver.

Key concepts: Hybrid III, Cadaver, Pelvis, Simulation, Mathematics, Computer science, Anatomy, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Hybrid III, Thor-α and PMHS Response in Frontal Sled Tests — Research Paper | ScholarLens