1988•Unpublished venueRequires access

Charpy impact test results of ferritic alloys irradiated to 10 DPA at 55/degree/C

W.L. Hu, D.S. Gelles

Open publisher page 0 citations

Abstract

Miniature Charpy specimens of HT-9 in base metal, weld metal and heat affected zone (HAZ) metal conditions, and 9Cr-1Mo in base metal and weld metal conditions have been tested following irradiation in the High Flux Isotope Reactor (HFIR) at 55/degree/C to /approximately/5 and 10 dpa. All specimens conditions are found to have degraded properties (both DBTT and USE). 9Cr-Mo degraded more than HT-9 and weld material performed worse than base metal which performed worse than HAZ material. As a function of dose, property degradation was approximately linear, indicating that degradation response had not saturated by 10 dpa. 11 refs., 2 figs., 3 tabs.

About this research paper

What this paper is about

Miniature Charpy specimens of HT-9 in base metal, weld metal and heat affected zone (HAZ) metal conditions, and 9Cr-1Mo in base metal and weld metal conditions have been tested following irradiation in the High Flux Isotope Reactor (HFIR) at 55/degree/C to /approximately/5 and 10 dpa. All specimens conditions are found to have degraded properties (both DBTT and USE). 9Cr-Mo degraded more than HT-9 and weld material performed worse than base metal which performed worse than HAZ material. As a function of dose, property degradation was approximately linear, indicating that degradation response had not saturated by 10 dpa. 11 refs., 2 figs., 3 tabs.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Miniature Charpy specimens of HT-9 in base metal, weld metal and heat affected zone (HAZ) metal conditions, and 9Cr-1Mo in base metal and weld metal conditions have been tested following irradiation in the High Flux Isotope Reactor (HFIR) at 55/degree/C to /approximately/5 and 10 dpa. All specimens conditions are found to have degraded properties (both DBTT and USE). 9Cr-Mo degraded more than HT-9 and weld material performed worse than base metal which performed worse than HAZ material. As a function of dose, property degradation was approximately linear, indicating that degradation response had not saturated by 10 dpa. 11 refs., 2 figs., 3 tabs.

Key concepts: Charpy impact test, Base metal, Materials science, Metallurgy, Welding, Irradiation, Degree (music), Metal

Related papers

Back to paper searchBrowse research topicsOriginal source
Charpy impact test results of ferritic alloys irradiated to 10 DPA at 55/degree/C — Research Paper | ScholarLens