Response of Airborne Mycoplasma pneumoniae to Abrupt Changes in Relative Humidity
M. T. Hatch, Daniel Nilsen Wright, G. D. Bailey
Abstract
Open-access reader
M. T. Hatch, Daniel Nilsen Wright, G. D. Bailey
Abstract
Open-access reader
The effect of an abrupt change in the relative humidity on the viability of airborne Mycoplasma pneumoniae has been examined. When the microbial aerosols were permitted to equilibrate in air held at either low or high humidities and were then subjected to a sudden shift to a mid-range humidity, a significant loss (>90%) of the colony-forming units per liter of aerosol occurred within 8 min. In contrast, a change in the relative humidity of more than 18% in either direction from a lethal mid-range humidity noticeably decreased the rate of biological decay. Double humidity shifts (i.e., from dry to a mid-range level and then to a high humidity range) were very detrimental, with very few survivors after 8 min. These results indicate that the biological stability of airborne M. pneumoniae may be easily modified by a sudden change in the relative humidity, such as occurs in natural atmospheres. This increased sensitivity brought about by producing changes in relative humidity through the lethal humidity range may provide a method whereby the control of these organisms in naturally contaminated indoor air environments may be eventually achieved.
OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The effect of an abrupt change in the relative humidity on the viability of airborne Mycoplasma pneumoniae has been examined. When the microbial aerosols were permitted to equilibrate in air held at either low or high humidities and were then subjected to a sudden shift to a mid-range humidity, a significant loss (>90%) of the colony-forming units per liter of aerosol occurred within 8 min. In contrast, a change in the relative humidity of more than 18% in either direction from a lethal mid-range humidity noticeably decreased the rate of biological decay. Double humidity shifts (i.e., from dry to a mid-range level and then to a high humidity range) were very detrimental, with very few survivors after 8 min. These results indicate that the biological stability of airborne M. pneumoniae may be easily modified by a sudden change in the relative humidity, such as occurs in natural atmospheres. This increased sensitivity brought about by producing changes in relative humidity through the lethal humidity range may provide a method whereby the control of these organisms in naturally contaminated indoor air environments may be eventually achieved.
Key concepts: Relative humidity, Humidity, Environmental science, Mycoplasma pneumoniae, Atmospheric sciences, Aerosol, Meteorology, Geography