1970Applied MicrobiologyOpen access

Response of Airborne Mycoplasma pneumoniae to Abrupt Changes in Relative Humidity

M. T. Hatch, Daniel Nilsen Wright, G. D. Bailey

Open full text 12 citations

Abstract

The effect of an abrupt change in the relative humidity on the viability of airborne Mycoplasma pneumoniae has been examined. When the microbial aerosols were permitted to equilibrate in air held at either low or high humidities and were then subjected to a sudden shift to a mid-range humidity, a significant loss (>90%) of the colony-forming units per liter of aerosol occurred within 8 min. In contrast, a change in the relative humidity of more than 18% in either direction from a lethal mid-range humidity noticeably decreased the rate of biological decay. Double humidity shifts (i.e., from dry to a mid-range level and then to a high humidity range) were very detrimental, with very few survivors after 8 min. These results indicate that the biological stability of airborne M. pneumoniae may be easily modified by a sudden change in the relative humidity, such as occurs in natural atmospheres. This increased sensitivity brought about by producing changes in relative humidity through the lethal humidity range may provide a method whereby the control of these organisms in naturally contaminated indoor air environments may be eventually achieved.

Open-access reader

About this research paper

What this paper is about

The effect of an abrupt change in the relative humidity on the viability of airborne Mycoplasma pneumoniae has been examined. When the microbial aerosols were permitted to equilibrate in air held at either low or high humidities and were then subjected to a sudden shift to a mid-range humidity, a significant loss (>90%) of the colony-forming units per liter of aerosol occurred within 8 min. In contrast, a change in the relative humidity of more than 18% in either direction from a lethal mid-range humidity noticeably decreased the rate of biological decay. Double humidity shifts (i.e., from dry to a mid-range level and then to a high humidity range) were very detrimental, with very few survivors after 8 min. These results indicate that the biological stability of airborne M. pneumoniae may be easily modified by a sudden change in the relative humidity, such as occurs in natural atmospheres. This increased sensitivity brought about by producing changes in relative humidity through the lethal humidity range may provide a method whereby the control of these organisms in naturally contaminated indoor air environments may be eventually achieved.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effect of an abrupt change in the relative humidity on the viability of airborne Mycoplasma pneumoniae has been examined. When the microbial aerosols were permitted to equilibrate in air held at either low or high humidities and were then subjected to a sudden shift to a mid-range humidity, a significant loss (>90%) of the colony-forming units per liter of aerosol occurred within 8 min. In contrast, a change in the relative humidity of more than 18% in either direction from a lethal mid-range humidity noticeably decreased the rate of biological decay. Double humidity shifts (i.e., from dry to a mid-range level and then to a high humidity range) were very detrimental, with very few survivors after 8 min. These results indicate that the biological stability of airborne M. pneumoniae may be easily modified by a sudden change in the relative humidity, such as occurs in natural atmospheres. This increased sensitivity brought about by producing changes in relative humidity through the lethal humidity range may provide a method whereby the control of these organisms in naturally contaminated indoor air environments may be eventually achieved.

Key concepts: Relative humidity, Humidity, Environmental science, Mycoplasma pneumoniae, Atmospheric sciences, Aerosol, Meteorology, Geography

Related papers

Back to paper searchBrowse research topicsOriginal source
Response of Airborne Mycoplasma pneumoniae to Abrupt Changes in Relative Humidity — Research Paper | ScholarLens