1977•Unpublished venueOpen access

Automated sample-processing and titration system for determining uranium in nuclear materials

Jackson E. Harrar, W.G. Boyle, J.D. Breshears, Charles L. Pomernacki, Hal R. Brand, Arthur M. Kray, R.J. Sherry, J.A. Pastrone

Open full text 1 citations

Abstract

The system is designed for accurate, precise, and selective determination of from 10 to 180 mg of uranium in 2 to 12 cm/sup 3/ of solution. Samples, standards, and their solutions are handled on a weight basis. These weights, together with their appropriate identification numbers, are stored in computer memory and are used automatically in the assay calculations after each titration. The measurement technique (controlled-current coulometry) is based on the Davies-Gray and New Brunswick Laboratory method, in which U(VI) is reduced to U(IV) in strong H/sub 3/PO/sub 4/, followed by titration of the U(IV) with electrogenerated V(V). Solution pretreatment and titration are automatic. The analyzer is able to process 44 samples per loading of the sample changer, at a rate of 4 to 9 samples per hour. The system includes a comprehensive fault-monitoring system that detects analytical errors, guards against abnormal conditions which might cause errors, and prevents unsafe operation. A detailed description of the system, information on the reliability of the component subsystems, and a summary of its evaluation by the New Brunswick Laboratory are presented.

Open-access reader

About this research paper

What this paper is about

The system is designed for accurate, precise, and selective determination of from 10 to 180 mg of uranium in 2 to 12 cm/sup 3/ of solution. Samples, standards, and their solutions are handled on a weight basis. These weights, together with their appropriate identification numbers, are stored in computer memory and are used automatically in the assay calculations after each titration. The measurement technique (controlled-current coulometry) is based on the Davies-Gray and New Brunswick Laboratory method, in which U(VI) is reduced to U(IV) in strong H/sub 3/PO/sub 4/, followed by titration of the U(IV) with electrogenerated V(V). Solution pretreatment and titration are automatic. The analyzer is able to process 44 samples per loading of the sample changer, at a rate of 4 to 9 samples per hour. The system includes a comprehensive fault-monitoring system that detects analytical errors, guards against abnormal conditions which might cause errors, and prevents unsafe operation. A detailed description of the system, information on the reliability of the component subsystems, and a summary of its evaluation by the New Brunswick Laboratory are presented.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The system is designed for accurate, precise, and selective determination of from 10 to 180 mg of uranium in 2 to 12 cm/sup 3/ of solution. Samples, standards, and their solutions are handled on a weight basis. These weights, together with their appropriate identification numbers, are stored in computer memory and are used automatically in the assay calculations after each titration. The measurement technique (controlled-current coulometry) is based on the Davies-Gray and New Brunswick Laboratory method, in which U(VI) is reduced to U(IV) in strong H/sub 3/PO/sub 4/, followed by titration of the U(IV) with electrogenerated V(V). Solution pretreatment and titration are automatic. The analyzer is able to process 44 samples per loading of the sample changer, at a rate of 4 to 9 samples per hour. The system includes a comprehensive fault-monitoring system that detects analytical errors, guards against abnormal conditions which might cause errors, and prevents unsafe operation. A detailed description of the system, information on the reliability of the component subsystems, and a summary of its evaluation by the New Brunswick Laboratory are presented.

Key concepts: Titration, Coulometry, Uranium, Spectrum analyzer, Chemistry, Sample (material), Analytical Chemistry (journal), Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Automated sample-processing and titration system for determining uranium in nuclear materials — Research Paper | ScholarLens