1995PubMedRequires access

[Transposition of the extensor indicis tendon in reconstruction of thumb extension after rupture of the extensor pollicis longus tendon].

S Winckler, Thomas Westphal, E. Brug

Open publisher page 8 citations

Abstract

During a period of 13 years we performed 56 extensor indicis proprius (EIP) transpositions for reconstruction of the ruptured or severed extensor pollicis longus tendon. The open injuries (n = 9) involved failed primary repair or untreated tendon injuries. The subcutaneous ruptures occurred after distal radius fractures (n = 17) or other closed injuries of the wrist (n = 10), without trauma in 14 patients and in 6 patients by rheumatoid synovialitis or collagenosis. 35 patients returned for follow-up examination 8 months to 10.5 years after operation. According to the evaluation scheme suggested by Geldmacher et al. we report 13 excellent, 19 good and 3 satisfactory results. Although several authors prefer EPL reconstruction with an intercalated tendon graft, we recommend the EIP transposition as a simple procedure with predictable satisfactory results.

About this research paper

What this paper is about

During a period of 13 years we performed 56 extensor indicis proprius (EIP) transpositions for reconstruction of the ruptured or severed extensor pollicis longus tendon. The open injuries (n = 9) involved failed primary repair or untreated tendon injuries. The subcutaneous ruptures occurred after distal radius fractures (n = 17) or other closed injuries of the wrist (n = 10), without trauma in 14 patients and in 6 patients by rheumatoid synovialitis or collagenosis. 35 patients returned for follow-up examination 8 months to 10.5 years after operation. According to the evaluation scheme suggested by Geldmacher et al. we report 13 excellent, 19 good and 3 satisfactory results. Although several authors prefer EPL reconstruction with an intercalated tendon graft, we recommend the EIP transposition as a simple procedure with predictable satisfactory results.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

During a period of 13 years we performed 56 extensor indicis proprius (EIP) transpositions for reconstruction of the ruptured or severed extensor pollicis longus tendon. The open injuries (n = 9) involved failed primary repair or untreated tendon injuries. The subcutaneous ruptures occurred after distal radius fractures (n = 17) or other closed injuries of the wrist (n = 10), without trauma in 14 patients and in 6 patients by rheumatoid synovialitis or collagenosis. 35 patients returned for follow-up examination 8 months to 10.5 years after operation. According to the evaluation scheme suggested by Geldmacher et al. we report 13 excellent, 19 good and 3 satisfactory results. Although several authors prefer EPL reconstruction with an intercalated tendon graft, we recommend the EIP transposition as a simple procedure with predictable satisfactory results.

Key concepts: Medicine, Tendon, Thumb, Surgery, Transposition (logic), Wrist, Anatomy, Linguistics

Related papers

Back to paper searchBrowse research topicsOriginal source
[Transposition of the extensor indicis tendon in reconstruction of thumb extension after rupture of the extensor pollicis longus tendon]. — Research Paper | ScholarLens