2000Purdue e-Pubs (Purdue University System)Requires access

Allowable Charge Calculation Method for Flammable Refrigerants

Osami Kataoka, Michito Yoshizawa, Taku Hirakawa

Open publisher page 16 citations

Abstract

Although hydrocarbons and lower GWP HFCs are flammable, they are preferable to high GWP HFCs from the perspective of mitigating climate change. Appropriate standards are necessary to utilize these refrigerants so that their flammability risks are minimized. Although standards for the use of flammable refrigerants exist, some reports indicate that the refrigerants can sometimes be ignited even at levels which satisfy the standards. In addition, the theoretical background of these standards is unclear. To promote the development of a more appropriate standard, a more scientific method for calculating the allowable refrigerant charge was established. Because the calculation method was proposed as the foundation for a new international standard, a relatively simple formula was developed, based on experimental and numerical (CFD) analyses. NOMENCLATURE CFD; Computational Fluid Dynamics h1; Effective height in 7m 2 room [m] GWP; Global Warming Potential K; Coefficient for adjusting charge amount HFC; Hydrofluorocarbons other than propane HCs; Hydrocarbons LFL; LFL in we1gm L kg/m] UFL; Upper Flammable Limit mmax; Allowable charge [kg] LFL; Lower Flammable limit t; Leak duration [minutes] A; Floor area [ m] x; Height from the floor [ m] h; Effective Height [m] y; Concentration of refrigerant [kg!m] h0 ; Leak height (Installation Height) [m]

About this research paper

What this paper is about

Although hydrocarbons and lower GWP HFCs are flammable, they are preferable to high GWP HFCs from the perspective of mitigating climate change. Appropriate standards are necessary to utilize these refrigerants so that their flammability risks are minimized. Although standards for the use of flammable refrigerants exist, some reports indicate that the refrigerants can sometimes be ignited even at levels which satisfy the standards. In addition, the theoretical background of these standards is unclear. To promote the development of a more appropriate standard, a more scientific method for calculating the allowable refrigerant charge was established. Because the calculation method was proposed as the foundation for a new international standard, a relatively simple formula was developed, based on experimental and numerical (CFD) analyses. NOMENCLATURE CFD; Computational Fluid Dynamics h1; Effective height in 7m 2 room [m] GWP; Global Warming Potential K; Coefficient for adjusting charge amount HFC; Hydrofluorocarbons other than propane HCs; Hydrocarbons LFL; LFL in we1gm L kg/m] UFL; Upper Flammable Limit mmax; Allowable charge [kg] LFL; Lower Flammable limit t; Leak duration [minutes] A; Floor area [ m] x; Height from the floor [ m] h; Effective Height [m] y; Concentration of refrigerant [kg!m] h0 ; Leak height (Installation Height) [m]

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Although hydrocarbons and lower GWP HFCs are flammable, they are preferable to high GWP HFCs from the perspective of mitigating climate change. Appropriate standards are necessary to utilize these refrigerants so that their flammability risks are minimized. Although standards for the use of flammable refrigerants exist, some reports indicate that the refrigerants can sometimes be ignited even at levels which satisfy the standards. In addition, the theoretical background of these standards is unclear. To promote the development of a more appropriate standard, a more scientific method for calculating the allowable refrigerant charge was established. Because the calculation method was proposed as the foundation for a new international standard, a relatively simple formula was developed, based on experimental and numerical (CFD) analyses. NOMENCLATURE CFD; Computational Fluid Dynamics h1; Effective height in 7m 2 room [m] GWP; Global Warming Potential K; Coefficient for adjusting charge amount HFC; Hydrofluorocarbons other than propane HCs; Hydrocarbons LFL; LFL in we1gm L kg/m] UFL; Upper Flammable Limit mmax; Allowable charge [kg] LFL; Lower Flammable limit t; Leak duration [minutes] A; Floor area [ m] x; Height from the floor [ m] h; Effective Height [m] y; Concentration of refrigerant [kg!m] h0 ; Leak height (Installation Height) [m]

Key concepts: Refrigerant, Flammable liquid, Global-warming potential, Flammability limit, Flammability, Environmental science, Meteorology, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source