1988•Chemical and Pharmaceutical BulletinOpen access

Enzyme sensors based on a coated-wire electrode. Effects of buffer concentration and pH on the potentiometric response of penicillin sensor.

CHIEN-WU CHEN, Jun Anzai, Tetsuo Osa

Open full text 6 citations

Abstract

The effects of pH and concentration of working buffer on the potentiometric response of a penicillin sensor based on a carboxyl-substituted poly(vinyl chloride)-coated Ag electrode were examined. The sensor showed a good response in buffer solutions of pH 6.5-8.5. The buffer concentration affected the response of the sensor. Higher concentration buffer (30 mM) strongly disturbed the response due to the higher buffer capacity.

Open-access reader

About this research paper

What this paper is about

The effects of pH and concentration of working buffer on the potentiometric response of a penicillin sensor based on a carboxyl-substituted poly(vinyl chloride)-coated Ag electrode were examined. The sensor showed a good response in buffer solutions of pH 6.5-8.5. The buffer concentration affected the response of the sensor. Higher concentration buffer (30 mM) strongly disturbed the response due to the higher buffer capacity.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effects of pH and concentration of working buffer on the potentiometric response of a penicillin sensor based on a carboxyl-substituted poly(vinyl chloride)-coated Ag electrode were examined. The sensor showed a good response in buffer solutions of pH 6.5-8.5. The buffer concentration affected the response of the sensor. Higher concentration buffer (30 mM) strongly disturbed the response due to the higher buffer capacity.

Key concepts: Buffer (optical fiber), Chemistry, Potentiometric titration, Buffer solution, Electrode, Penicillin, Phosphate buffered saline, Vinyl chloride

Related papers

Back to paper searchBrowse research topicsOriginal source
Enzyme sensors based on a coated-wire electrode. Effects of buffer concentration and pH on the potentiometric response of penicillin sensor. — Research Paper | ScholarLens