Effect of continuous positive pressure ventilation on cardiac output.
Jonathan Giordano, Alden H. Harken
Abstract
Jonathan Giordano, Alden H. Harken
Abstract
Ten mongrel dogs were placed on 5 and 10 cm. H20 of CPPV. Cardiac output, pulmonary vascular resistance and pleural pressures were measured. At 5 cm. H20/CPPV there was no significant change in cardiac output or pulmonary vascular resistance. At 10 cm. H20 CPPV cardiac output significantly decreased and pulmonary vascular resistance increased. The physiologic basis for these changes is discussed and related to the clinical situation.
OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Ten mongrel dogs were placed on 5 and 10 cm. H20 of CPPV. Cardiac output, pulmonary vascular resistance and pleural pressures were measured. At 5 cm. H20/CPPV there was no significant change in cardiac output or pulmonary vascular resistance. At 10 cm. H20 CPPV cardiac output significantly decreased and pulmonary vascular resistance increased. The physiologic basis for these changes is discussed and related to the clinical situation.
Key concepts: Medicine, Cardiac output, Vascular resistance, Cardiology, Internal medicine, Ventilation (architecture), Anesthesia, Hemodynamics