2002•Unpublished venueRequires access

A passive crowbar switch for high voltage operation

F.A. Tuema, S.J. MacGregor, S.M. Turnbull

Open publisher page 3 citations

Abstract

This paper describes the development of a water-filled passive crowbar switch which is employed to divert energy away from sensitive loads at voltage levels up to 600 kV. The crowbar is self-closing and does not require electrical triggering. The time delay to crowbar operation is determined by the magnitude of the applied impulse voltage and the switch gap spacing. The switch is comprised of a highly nonuniform field electrode configuration immersed in de-ionised water. Electrostatic field analysis of the switch was carried out in order to optimise the insulation performance of the device prior to testing. Characterisation of the passive crowbar switch was accomplished using a Marx generator as the impulse voltage source, and by measuring the time delay to breakdown for different values of applied voltage and electrode spacing. The results have shown that the crowbar design is capable of operating at voltages up to 600 kV.

About this research paper

What this paper is about

This paper describes the development of a water-filled passive crowbar switch which is employed to divert energy away from sensitive loads at voltage levels up to 600 kV. The crowbar is self-closing and does not require electrical triggering. The time delay to crowbar operation is determined by the magnitude of the applied impulse voltage and the switch gap spacing. The switch is comprised of a highly nonuniform field electrode configuration immersed in de-ionised water. Electrostatic field analysis of the switch was carried out in order to optimise the insulation performance of the device prior to testing. Characterisation of the passive crowbar switch was accomplished using a Marx generator as the impulse voltage source, and by measuring the time delay to breakdown for different values of applied voltage and electrode spacing. The results have shown that the crowbar design is capable of operating at voltages up to 600 kV.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper describes the development of a water-filled passive crowbar switch which is employed to divert energy away from sensitive loads at voltage levels up to 600 kV. The crowbar is self-closing and does not require electrical triggering. The time delay to crowbar operation is determined by the magnitude of the applied impulse voltage and the switch gap spacing. The switch is comprised of a highly nonuniform field electrode configuration immersed in de-ionised water. Electrostatic field analysis of the switch was carried out in order to optimise the insulation performance of the device prior to testing. Characterisation of the passive crowbar switch was accomplished using a Marx generator as the impulse voltage source, and by measuring the time delay to breakdown for different values of applied voltage and electrode spacing. The results have shown that the crowbar design is capable of operating at voltages up to 600 kV.

Key concepts: Crowbar, Voltage, High voltage, Impulse (physics), Electrical engineering, Marx generator, Impulse generator, Generator (circuit theory)

Related papers

Back to paper searchBrowse research topicsOriginal source
A passive crowbar switch for high voltage operation — Research Paper | ScholarLens