2002The International Journal of Tuberculosis and Lung DiseaseRequires access

Low plasma concentrations of rifampicin in tuberculosis patients in Indonesia

Reinout van Crevel, Bachti Alisjahbana, Cheng Ma, F Borst, Halim Danusantoso, Wenpeng Ma, Divan A. Burger, H. Nelwan R. H.

Open publisher page 74 citations

Abstract

SETTING: Although rifampicin is a key drug in tuberculosis treatment, little is known about its quality and bioavailability in countries endemic for tuberculosis. High drug levels may lead to increased toxicity, while low drug levels may predispose to treatment failure and relapse. OBJECTIVE: To investigate possible variations in the bioavailability of plasma rifampicin in tuberculosis patients in Indonesia. DESIGN: Plasma concentrations of rifampicin and the rifampicin content of drug formulations in use were measured among 62 non-selected tuberculosis patients in Jakarta, Indonesia. RESULTS: Plasma concentrations of rifampin were generally low: 70% of patients had 2-hour plasma concentrations (Cmax) below 4 mg/L. No toxic plasma concentrations of rifampicin (>20 mg/L) were found. The strongest predictive factor for the magnitude of rifampicin concentrations was the drug manufacturer. The rifampicin content of the different drug preparations used was normal (90.5-103.6% of the reference standard). No association was found between low plasma rifampicin concentrations and delayed sputum conversion or treatment failure. CONCLUSION: The unexpectedly low plasma concentrations of rifampicin in this setting are most likely due to reduced bioavailability of local drug preparations, as the rifampicin content of the drug preparations was found to be normal. The clinical significance of these findings remains to be determined.

About this research paper

What this paper is about

SETTING: Although rifampicin is a key drug in tuberculosis treatment, little is known about its quality and bioavailability in countries endemic for tuberculosis. High drug levels may lead to increased toxicity, while low drug levels may predispose to treatment failure and relapse. OBJECTIVE: To investigate possible variations in the bioavailability of plasma rifampicin in tuberculosis patients in Indonesia. DESIGN: Plasma concentrations of rifampicin and the rifampicin content of drug formulations in use were measured among 62 non-selected tuberculosis patients in Jakarta, Indonesia. RESULTS: Plasma concentrations of rifampin were generally low: 70% of patients had 2-hour plasma concentrations (Cmax) below 4 mg/L. No toxic plasma concentrations of rifampicin (>20 mg/L) were found. The strongest predictive factor for the magnitude of rifampicin concentrations was the drug manufacturer. The rifampicin content of the different drug preparations used was normal (90.5-103.6% of the reference standard). No association was found between low plasma rifampicin concentrations and delayed sputum conversion or treatment failure. CONCLUSION: The unexpectedly low plasma concentrations of rifampicin in this setting are most likely due to reduced bioavailability of local drug preparations, as the rifampicin content of the drug preparations was found to be normal. The clinical significance of these findings remains to be determined.

Why it matters

OpenAlex reports 74 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

SETTING: Although rifampicin is a key drug in tuberculosis treatment, little is known about its quality and bioavailability in countries endemic for tuberculosis. High drug levels may lead to increased toxicity, while low drug levels may predispose to treatment failure and relapse. OBJECTIVE: To investigate possible variations in the bioavailability of plasma rifampicin in tuberculosis patients in Indonesia. DESIGN: Plasma concentrations of rifampicin and the rifampicin content of drug formulations in use were measured among 62 non-selected tuberculosis patients in Jakarta, Indonesia. RESULTS: Plasma concentrations of rifampin were generally low: 70% of patients had 2-hour plasma concentrations (Cmax) below 4 mg/L. No toxic plasma concentrations of rifampicin (>20 mg/L) were found. The strongest predictive factor for the magnitude of rifampicin concentrations was the drug manufacturer. The rifampicin content of the different drug preparations used was normal (90.5-103.6% of the reference standard). No association was found between low plasma rifampicin concentrations and delayed sputum conversion or treatment failure. CONCLUSION: The unexpectedly low plasma concentrations of rifampicin in this setting are most likely due to reduced bioavailability of local drug preparations, as the rifampicin content of the drug preparations was found to be normal. The clinical significance of these findings remains to be determined.

Key concepts: Rifampicin, Medicine, Bioavailability, Tuberculosis, Drug, Pharmacology, Cmax, Sputum

Related papers

Back to paper searchBrowse research topicsOriginal source
Low plasma concentrations of rifampicin in tuberculosis patients in Indonesia — Research Paper | ScholarLens