2014•Unpublished venueRequires access

Optimization of the heating load operation of large co-generation units in thermal power plant

Haisheng Yang, Shengyang Lu

Open publisher page 7 citations

Abstract

The optimization of the heating load operation of large co-generation units in thermal power plant was described, and the evaluation method of maximizing total relative economic benefit for thermal power plant was put forward. It is shown that this method can provide objective economic benefit of district heating operation conditions, and the benefit has no relationship with the concrete energy allocation method used for heating and electricity. It is shown that under the condition of boilers full load operation the optimized heating load scheme is related to the electric power response characteristics with change of the heating steam supply for the individual cogeneration unit. An example of heating load optimization for 2 existing 330MW cogeneration units was put forward in detail. It is shown that, the electric power response characteristics with change of the heating steam supply for the individual cogeneration unit, especially the slope of the characteristic curve determines the heating load optimization results. The cogeneration unit with lower changing slope should be dispatched in higher priority.

About this research paper

What this paper is about

The optimization of the heating load operation of large co-generation units in thermal power plant was described, and the evaluation method of maximizing total relative economic benefit for thermal power plant was put forward. It is shown that this method can provide objective economic benefit of district heating operation conditions, and the benefit has no relationship with the concrete energy allocation method used for heating and electricity. It is shown that under the condition of boilers full load operation the optimized heating load scheme is related to the electric power response characteristics with change of the heating steam supply for the individual cogeneration unit. An example of heating load optimization for 2 existing 330MW cogeneration units was put forward in detail. It is shown that, the electric power response characteristics with change of the heating steam supply for the individual cogeneration unit, especially the slope of the characteristic curve determines the heating load optimization results. The cogeneration unit with lower changing slope should be dispatched in higher priority.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The optimization of the heating load operation of large co-generation units in thermal power plant was described, and the evaluation method of maximizing total relative economic benefit for thermal power plant was put forward. It is shown that this method can provide objective economic benefit of district heating operation conditions, and the benefit has no relationship with the concrete energy allocation method used for heating and electricity. It is shown that under the condition of boilers full load operation the optimized heating load scheme is related to the electric power response characteristics with change of the heating steam supply for the individual cogeneration unit. An example of heating load optimization for 2 existing 330MW cogeneration units was put forward in detail. It is shown that, the electric power response characteristics with change of the heating steam supply for the individual cogeneration unit, especially the slope of the characteristic curve determines the heating load optimization results. The cogeneration unit with lower changing slope should be dispatched in higher priority.

Key concepts: Cogeneration, Base load power plant, Power (physics), Thermal power station, Electricity generation, Electric heating, Electricity, Electrical load

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimization of the heating load operation of large co-generation units in thermal power plant — Research Paper | ScholarLens