Prognosis for recovery of function in acute renal failure. Value of the renal image obtained using iodohippurate sodium I 131
Theodore H. Harwood
Abstract
Theodore H. Harwood
Abstract
Twenty-four survivors of acute, nonobstructive, nonnephritic renal failure had a renal scan using iodohippurate sodium I 131 performed early in the acute illness. Scans were judged according to whether the renal images were prominent, faint, or absent during the first 30 minutes after intravenous injection of 100 to 250 microcuries of iodohippurate sodium I 131. All ten patients with prominent renal images attained life-sustaining renal function with an average postrecovery creatinine clearance of 80 ml/min. Of the seven patients with faint renal images, six recovered life-sustaining renal function (average creatinine clearance of 39 ml/min), and one required chronic hemodialysis. Seven patients had no renal image initially; four recovered life-sustaining renal function with an average creatinine clearance of 25 ml/min; three required chronic hemodialysis. We conclude that, for patients with acute renal failure, the appearance of the renal image obtained using this substance is an important indicator of renal viability and of the likelihood for functional recovery.
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Twenty-four survivors of acute, nonobstructive, nonnephritic renal failure had a renal scan using iodohippurate sodium I 131 performed early in the acute illness. Scans were judged according to whether the renal images were prominent, faint, or absent during the first 30 minutes after intravenous injection of 100 to 250 microcuries of iodohippurate sodium I 131. All ten patients with prominent renal images attained life-sustaining renal function with an average postrecovery creatinine clearance of 80 ml/min. Of the seven patients with faint renal images, six recovered life-sustaining renal function (average creatinine clearance of 39 ml/min), and one required chronic hemodialysis. Seven patients had no renal image initially; four recovered life-sustaining renal function with an average creatinine clearance of 25 ml/min; three required chronic hemodialysis. We conclude that, for patients with acute renal failure, the appearance of the renal image obtained using this substance is an important indicator of renal viability and of the likelihood for functional recovery.
Key concepts: Renal function, Medicine, Hemodialysis, Creatinine, Urology, Chronic renal failure, Internal medicine