Proposition and Evaluation of a Novel Method Based on Videogrammetry to Measure Three-Dimensional Rib Motion during Breathing
Karine Jacon Sarro, Amanda Piaia Silvatti, Andréa Aliverti, Ricardo Machado Leite de Barros
Abstract
Karine Jacon Sarro, Amanda Piaia Silvatti, Andréa Aliverti, Ricardo Machado Leite de Barros
Abstract
A novel method based on kinematical analysis is proposed to describe the three-dimensional motion of the ribs during breathing. The three-dimensional coordinates of markers on the ribs and vertebrae were used to calculate the orientation of the ribs as a function of time. A test measured the relative motion between the markers and the ribs using magnetic resonance and the results revealed that the skin motion artifact found for the ribs (absolute mean value 3.9 mm) would induce maximum errors of 4 degrees on rib motion calculation. The method identified a signal coherent with the breathing cycle for the angles of the ribs around the mediolateral axis and was also able to show differences between healthy nonathletes and swimmers, which presented greater angular variation of the ribs (p < .05). In conclusion, this study has shown the reliability of using three-dimensional kinematic analysis to evaluate the movement of the ribs during breathing as well as its potential to identify differences in the behavior of the rib motion in trained swimmers and untrained healthy subjects.
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A novel method based on kinematical analysis is proposed to describe the three-dimensional motion of the ribs during breathing. The three-dimensional coordinates of markers on the ribs and vertebrae were used to calculate the orientation of the ribs as a function of time. A test measured the relative motion between the markers and the ribs using magnetic resonance and the results revealed that the skin motion artifact found for the ribs (absolute mean value 3.9 mm) would induce maximum errors of 4 degrees on rib motion calculation. The method identified a signal coherent with the breathing cycle for the angles of the ribs around the mediolateral axis and was also able to show differences between healthy nonathletes and swimmers, which presented greater angular variation of the ribs (p < .05). In conclusion, this study has shown the reliability of using three-dimensional kinematic analysis to evaluate the movement of the ribs during breathing as well as its potential to identify differences in the behavior of the rib motion in trained swimmers and untrained healthy subjects.
Key concepts: Rib cage, Breathing, Kinematics, Artifact (error), Motion (physics), Anatomy, Mathematics, Physics