2015IEEE Transactions on Industry ApplicationsRequires access

Novel Simple Reactive Power Control Strategy With DC Capacitor Voltage Control for Active Load Balancer in Three-Phase Four-Wire Distribution Systems

Tint Soe Win, Yoshihiro Hisada, Toshihiko P. Tanaka, Eiji Hiraki, Masayuki Okamoto, Seong Ryong Lee

Open publisher page 27 citations

Abstract

This paper proposes a novel simple reactive power control strategy for the active load balancer (ALB) in three-phase four-wire distribution systems. The proposed reactive power control strategy may be applicable for adjustment of the source-side power factor under the balanced load condition. Only dc capacitor voltage control is used in the proposed control strategy. Therefore, the calculation blocks of the active and reactive components of the load currents are not necessary. The authors, thus, offer the simplest control strategy to control reactive power under the balanced load condition on three-phase four-wire distribution feeders. The basic principle of dc-capacitor-voltage-control-based reactive power control strategy is discussed in detail and then confirmed by digital computer simulation. A prototype experimental system was constructed and tested. Experimental results demonstrate that balanced source currents with reactive power control are achieved on three-phase four-wire distribution feeders. These experimental results also demonstrate that controlling the reactive power reduces the required power rating of the ALB compared with that of the conventional unity power factor control strategy.

About this research paper

What this paper is about

This paper proposes a novel simple reactive power control strategy for the active load balancer (ALB) in three-phase four-wire distribution systems. The proposed reactive power control strategy may be applicable for adjustment of the source-side power factor under the balanced load condition. Only dc capacitor voltage control is used in the proposed control strategy. Therefore, the calculation blocks of the active and reactive components of the load currents are not necessary. The authors, thus, offer the simplest control strategy to control reactive power under the balanced load condition on three-phase four-wire distribution feeders. The basic principle of dc-capacitor-voltage-control-based reactive power control strategy is discussed in detail and then confirmed by digital computer simulation. A prototype experimental system was constructed and tested. Experimental results demonstrate that balanced source currents with reactive power control are achieved on three-phase four-wire distribution feeders. These experimental results also demonstrate that controlling the reactive power reduces the required power rating of the ALB compared with that of the conventional unity power factor control strategy.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper proposes a novel simple reactive power control strategy for the active load balancer (ALB) in three-phase four-wire distribution systems. The proposed reactive power control strategy may be applicable for adjustment of the source-side power factor under the balanced load condition. Only dc capacitor voltage control is used in the proposed control strategy. Therefore, the calculation blocks of the active and reactive components of the load currents are not necessary. The authors, thus, offer the simplest control strategy to control reactive power under the balanced load condition on three-phase four-wire distribution feeders. The basic principle of dc-capacitor-voltage-control-based reactive power control strategy is discussed in detail and then confirmed by digital computer simulation. A prototype experimental system was constructed and tested. Experimental results demonstrate that balanced source currents with reactive power control are achieved on three-phase four-wire distribution feeders. These experimental results also demonstrate that controlling the reactive power reduces the required power rating of the ALB compared with that of the conventional unity power factor control strategy.

Key concepts: AC power, Power factor, Volt-ampere reactive, Capacitor, Control theory (sociology), Three-phase, Power control, Power (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Novel Simple Reactive Power Control Strategy With DC Capacitor Voltage Control for Active Load Balancer in Three-Phase Four-Wire Distribution Systems — Research Paper | ScholarLens