Development and validation of simultaneous spectrophotometric methods for drotaverine hydrochloride and aceclofenac from tablet dosage form.
Shailesh Amritlal Shah, Dinesh R. Shah, RS Chauhan, Jyotesh R Jain
Abstract
Shailesh Amritlal Shah, Dinesh R. Shah, RS Chauhan, Jyotesh R Jain
Abstract
Two simple spectrophotometric methods have been developed for simultaneous estimation of drotaverine hydrochloride and aceclofenac from tablet dosage form. Method I is a simultaneous equation method (Vierodt's method), wavelengths selected are 306.5 and 276 nm. Method II is the absorbance ratio method (Q-Analysis), which employs 298.5 nm as λ(1) and 276 nm as λ(2) (λmax of AF) for formation of equations. Both the methods were found to be linear between the range of 8-32 μg/ml for drotaverine and 10-40 μg/ml for aceclofenac. The accuracy and precision were determined and found to comply with ICH guidelines. Both the methods showed good reproducibility and recovery with % RSD in the desired range. The methods were found to be rapid, specific, precise and accurate and can be successfully applied for the routine analysis of drotaverine and aceclofenac in their combined tablet dosage form.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Two simple spectrophotometric methods have been developed for simultaneous estimation of drotaverine hydrochloride and aceclofenac from tablet dosage form. Method I is a simultaneous equation method (Vierodt's method), wavelengths selected are 306.5 and 276 nm. Method II is the absorbance ratio method (Q-Analysis), which employs 298.5 nm as λ(1) and 276 nm as λ(2) (λmax of AF) for formation of equations. Both the methods were found to be linear between the range of 8-32 μg/ml for drotaverine and 10-40 μg/ml for aceclofenac. The accuracy and precision were determined and found to comply with ICH guidelines. Both the methods showed good reproducibility and recovery with % RSD in the desired range. The methods were found to be rapid, specific, precise and accurate and can be successfully applied for the routine analysis of drotaverine and aceclofenac in their combined tablet dosage form.
Key concepts: Aceclofenac, Dosage form, Absorbance, Reproducibility, Chromatography, Chemistry, Mathematics, Biomedical engineering