2000Unpublished venueRequires access

Fire Testing of Electrical Materials

MM Hirschler

Open publisher page 2 citations

Abstract

In recent years electrical wire or cable insulation has been, once more, identified by NFPA statistics as a major material first ignited in residential fires (representing 7.6% of fires and 3.9% of fire fatalities in 1991–95) and the cause of 13% of catastrophic fires (1993–96). This highlights the need for renewed emphasis on fire testing of wires, cables and electrical materials. Cable fire tests can be subdivided into 5 categories: (a) Old fashioned small scale tests, which generally address only ignitability or flame spread, but the results of which are rarely meaningful in terms of real fire performance; (b) Vertical cable tray tests, of which there are a large variety, ranging in heat input from 20 kW up to 154 kW (in the case of riser cables), which address flame spread, and sometimes also smoke and heat release; (c) The Steiner tunnel NFPA 262 (UL 910) test, which determines wind aided horizontal flame spread, and smoke release, under a very high heat input (ca. 90 kW), with a relatively small mass load of cables; and (d) Small scale cable tests, often originally designed for materials, directed at measuring fundamental fire properties, such as heat release or critical fluxes for ignition or flame spread and thermal heating properties. (e) Tests for other cable fire properties, mainly smoke (obscuration, toxicity, corrosivity) and circuit integrity.

About this research paper

What this paper is about

In recent years electrical wire or cable insulation has been, once more, identified by NFPA statistics as a major material first ignited in residential fires (representing 7.6% of fires and 3.9% of fire fatalities in 1991–95) and the cause of 13% of catastrophic fires (1993–96). This highlights the need for renewed emphasis on fire testing of wires, cables and electrical materials. Cable fire tests can be subdivided into 5 categories: (a) Old fashioned small scale tests, which generally address only ignitability or flame spread, but the results of which are rarely meaningful in terms of real fire performance; (b) Vertical cable tray tests, of which there are a large variety, ranging in heat input from 20 kW up to 154 kW (in the case of riser cables), which address flame spread, and sometimes also smoke and heat release; (c) The Steiner tunnel NFPA 262 (UL 910) test, which determines wind aided horizontal flame spread, and smoke release, under a very high heat input (ca. 90 kW), with a relatively small mass load of cables; and (d) Small scale cable tests, often originally designed for materials, directed at measuring fundamental fire properties, such as heat release or critical fluxes for ignition or flame spread and thermal heating properties. (e) Tests for other cable fire properties, mainly smoke (obscuration, toxicity, corrosivity) and circuit integrity.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In recent years electrical wire or cable insulation has been, once more, identified by NFPA statistics as a major material first ignited in residential fires (representing 7.6% of fires and 3.9% of fire fatalities in 1991–95) and the cause of 13% of catastrophic fires (1993–96). This highlights the need for renewed emphasis on fire testing of wires, cables and electrical materials. Cable fire tests can be subdivided into 5 categories: (a) Old fashioned small scale tests, which generally address only ignitability or flame spread, but the results of which are rarely meaningful in terms of real fire performance; (b) Vertical cable tray tests, of which there are a large variety, ranging in heat input from 20 kW up to 154 kW (in the case of riser cables), which address flame spread, and sometimes also smoke and heat release; (c) The Steiner tunnel NFPA 262 (UL 910) test, which determines wind aided horizontal flame spread, and smoke release, under a very high heat input (ca. 90 kW), with a relatively small mass load of cables; and (d) Small scale cable tests, often originally designed for materials, directed at measuring fundamental fire properties, such as heat release or critical fluxes for ignition or flame spread and thermal heating properties. (e) Tests for other cable fire properties, mainly smoke (obscuration, toxicity, corrosivity) and circuit integrity.

Key concepts: Materials science, Forensic engineering, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Fire Testing of Electrical Materials — Research Paper | ScholarLens