Clinical comparison of the Welch Allyn SureSight™ handheld autorefractor vs. streak retinoscopy in dogs
Allyson D. Groth, Steven R. Hollingsworth, Ron Ofri, Philip H. Kass, Zoe Reed, Christopher John Murphy
Abstract
Allyson D. Groth, Steven R. Hollingsworth, Ron Ofri, Philip H. Kass, Zoe Reed, Christopher John Murphy
Abstract
OBJECTIVE: To compare the Welch Allyn SureSight™ wavefront autorefractor with retinoscopy in normal dogs. ANIMALS STUDIED: Fifty privately owned dogs (100 eyes) of 20 breeds, free of ocular disease. Mean ± SD age: 5.7 ± 3.25 years (range: 6 months-13 years). PROCEDURES: The refractive error was determined in each eye by two experienced retinoscopists using streak retinoscopy as well as by an autorefractor operated by two different examiners. Measurements were performed before and approximately 30-45 min after cycloplegia was induced by cyclopentolate 0.5% and tropicamide 0.5% ophthalmic solutions. RESULTS: Mean ± SD noncyclopleged retinoscopy net sphere was -0.55 ± 1.14 (range: -3.75 to 3.5) diopters (D). Mean cyclopleged retinoscopy net sphere was -0.52 ± 1.18 (range: -4.25 to 2) D. Mean ± SD noncyclopleged autorefractor spherical equivalent (SE) was -0.42 ± 1.13 D (range: -3.36 to 2.73) D. Mean cyclopleged autorefractor SE was 0.10 ± 1.47 (range: -5.62 to 3.19) D. Noncyclopleged autorefraction results were not significantly different from streak retinoscopy (whether noncyclopleged or cyclopleged, P = 0.80 and P = 0.26, respectively). Cyclopleged autorefraction results were significantly different from noncyclopleged or cyclopleged streak retinoscopy (P < 0.0001 in both states). There was no significant difference between noncyclopleged and cyclopleged streak retinoscopy (P = 0.97). CONCLUSIONS: Noncyclopleged autorefraction shows good agreement with streak retinoscopy in dogs and may be a useful clinical technique. Cycloplegia does not significantly affect streak retinoscopy results in dogs.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To compare the Welch Allyn SureSight™ wavefront autorefractor with retinoscopy in normal dogs. ANIMALS STUDIED: Fifty privately owned dogs (100 eyes) of 20 breeds, free of ocular disease. Mean ± SD age: 5.7 ± 3.25 years (range: 6 months-13 years). PROCEDURES: The refractive error was determined in each eye by two experienced retinoscopists using streak retinoscopy as well as by an autorefractor operated by two different examiners. Measurements were performed before and approximately 30-45 min after cycloplegia was induced by cyclopentolate 0.5% and tropicamide 0.5% ophthalmic solutions. RESULTS: Mean ± SD noncyclopleged retinoscopy net sphere was -0.55 ± 1.14 (range: -3.75 to 3.5) diopters (D). Mean cyclopleged retinoscopy net sphere was -0.52 ± 1.18 (range: -4.25 to 2) D. Mean ± SD noncyclopleged autorefractor spherical equivalent (SE) was -0.42 ± 1.13 D (range: -3.36 to 2.73) D. Mean cyclopleged autorefractor SE was 0.10 ± 1.47 (range: -5.62 to 3.19) D. Noncyclopleged autorefraction results were not significantly different from streak retinoscopy (whether noncyclopleged or cyclopleged, P = 0.80 and P = 0.26, respectively). Cyclopleged autorefraction results were significantly different from noncyclopleged or cyclopleged streak retinoscopy (P < 0.0001 in both states). There was no significant difference between noncyclopleged and cyclopleged streak retinoscopy (P = 0.97). CONCLUSIONS: Noncyclopleged autorefraction shows good agreement with streak retinoscopy in dogs and may be a useful clinical technique. Cycloplegia does not significantly affect streak retinoscopy results in dogs.
Key concepts: Retinoscopy, Cycloplegia, Autorefractor, Streak, Dioptre, Ophthalmology, Refractive error, Optometry