OBJECTIVE: The purpose of this investigation was to study the relationship between the lactate (LT) and the ventilatory threshold (VT) during a ramp protocol in cycle ergometry. PARTICIPANTS: Thirty nine trained male subjects were selected as subjects. EXPERIMENTAL DESIGN: All the subjects performed a maximal ergometric test on a cycle ergometer consisting of a ramp protocol (increases of 25 W.min-1). The anaerobic threshold (AT) was determined using both ventilatory gas analysis (VT) and lactate measurement (LT). All the data related to the VT and LT were expressed in work rate (W), VO2 (ml.kg-1.min-1) and heart rate (bpm) and expressed as mean and standard deviation. Lactate threshold (LT) and ventilatory threshold (VT) were compared using the Student's "t"-test for paired data. Correlation coefficients between both variables were also calculated. Statistical significance was accepted at the 5% level. RESULTS: Results showed significant differences (p < 0.05) between mean values of VT and LT when both expressed either as heart rate (bpm), work rate (W), or VO2 (ml.kg-1.min-1). CONCLUSIONS: It was concluded that LT and VT occur at different exercise intensities during ramp protocol exercise on a cycle ergometer.
OpenAlex reports 31 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: The purpose of this investigation was to study the relationship between the lactate (LT) and the ventilatory threshold (VT) during a ramp protocol in cycle ergometry. PARTICIPANTS: Thirty nine trained male subjects were selected as subjects. EXPERIMENTAL DESIGN: All the subjects performed a maximal ergometric test on a cycle ergometer consisting of a ramp protocol (increases of 25 W.min-1). The anaerobic threshold (AT) was determined using both ventilatory gas analysis (VT) and lactate measurement (LT). All the data related to the VT and LT were expressed in work rate (W), VO2 (ml.kg-1.min-1) and heart rate (bpm) and expressed as mean and standard deviation. Lactate threshold (LT) and ventilatory threshold (VT) were compared using the Student's "t"-test for paired data. Correlation coefficients between both variables were also calculated. Statistical significance was accepted at the 5% level. RESULTS: Results showed significant differences (p < 0.05) between mean values of VT and LT when both expressed either as heart rate (bpm), work rate (W), or VO2 (ml.kg-1.min-1). CONCLUSIONS: It was concluded that LT and VT occur at different exercise intensities during ramp protocol exercise on a cycle ergometer.
Key concepts: Anaerobic exercise, Ventilatory threshold, Cycle ergometer, Heart rate, Lactate threshold, Bicycle ergometer, Medicine, Cardiology