2013International Journal of Medical & Pharmaceutical SciencesRequires access

UTILITY OF CALCULATED GLOMERULAR FILTRATION RATE IN EVALUATION OF KIDNEY FUNCTION

Amit Sonagra, A. Veena, K Dattatreya, D.S. Jayaprakash Murthy

Open publisher page 0 citations

Abstract

Background: Chronic kidney disease (CKD) is characterized by glomerular filtration rate (GFR) <60mL/min/1.73m 2 for ≥3months regardless of the underlying cause. Serum creatinine is commonly used investigation to evaluate renal function. Because of large reserve capacity of kidney, serum creatinine level may remain within normal limit evenif GFR is significantly decreased. Objectives: This study was done to evaluate utility and superiority of calculated GFR (eGFR) over serum creatinine level to detect kidney function impairment. Materials and methods: forty subjects with chronic renal disease were selected for the present study. Serum creatinine level was estimated using commercially available kit based on Jaffe’s method. Creatinine clearance was calculated using Cockcroft-Gault’s formula and GFR was calculated using MDRD formula. Results: Majority of the patients were at stage III and stage IV of CKD as per NKF-KDOQI guideline. Out of 40 patients, 8 patients were having serum creatinine level<1.3mg/dL but 6 patients out of those 8 were having GFR<60mL/min/1.73m 2 . Conclusion: Use of these formulae for evaluation of GFR can be useful to detect the patients with abnormal GFR in spite of having normal serum creatinine level. Such cases can be missed if clinicians rely only upon serum creatinine value. These formulae may prove an economical alternate to direct measurement of GFR.

About this research paper

What this paper is about

Background: Chronic kidney disease (CKD) is characterized by glomerular filtration rate (GFR) <60mL/min/1.73m 2 for ≥3months regardless of the underlying cause. Serum creatinine is commonly used investigation to evaluate renal function. Because of large reserve capacity of kidney, serum creatinine level may remain within normal limit evenif GFR is significantly decreased. Objectives: This study was done to evaluate utility and superiority of calculated GFR (eGFR) over serum creatinine level to detect kidney function impairment. Materials and methods: forty subjects with chronic renal disease were selected for the present study. Serum creatinine level was estimated using commercially available kit based on Jaffe’s method. Creatinine clearance was calculated using Cockcroft-Gault’s formula and GFR was calculated using MDRD formula. Results: Majority of the patients were at stage III and stage IV of CKD as per NKF-KDOQI guideline. Out of 40 patients, 8 patients were having serum creatinine level<1.3mg/dL but 6 patients out of those 8 were having GFR<60mL/min/1.73m 2 . Conclusion: Use of these formulae for evaluation of GFR can be useful to detect the patients with abnormal GFR in spite of having normal serum creatinine level. Such cases can be missed if clinicians rely only upon serum creatinine value. These formulae may prove an economical alternate to direct measurement of GFR.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: Chronic kidney disease (CKD) is characterized by glomerular filtration rate (GFR) <60mL/min/1.73m 2 for ≥3months regardless of the underlying cause. Serum creatinine is commonly used investigation to evaluate renal function. Because of large reserve capacity of kidney, serum creatinine level may remain within normal limit evenif GFR is significantly decreased. Objectives: This study was done to evaluate utility and superiority of calculated GFR (eGFR) over serum creatinine level to detect kidney function impairment. Materials and methods: forty subjects with chronic renal disease were selected for the present study. Serum creatinine level was estimated using commercially available kit based on Jaffe’s method. Creatinine clearance was calculated using Cockcroft-Gault’s formula and GFR was calculated using MDRD formula. Results: Majority of the patients were at stage III and stage IV of CKD as per NKF-KDOQI guideline. Out of 40 patients, 8 patients were having serum creatinine level<1.3mg/dL but 6 patients out of those 8 were having GFR<60mL/min/1.73m 2 . Conclusion: Use of these formulae for evaluation of GFR can be useful to detect the patients with abnormal GFR in spite of having normal serum creatinine level. Such cases can be missed if clinicians rely only upon serum creatinine value. These formulae may prove an economical alternate to direct measurement of GFR.

Key concepts: Renal function, Creatinine, Urology, Kidney disease, Medicine, Kidney, Internal medicine, Endocrinology

Related papers

Back to paper searchBrowse research topicsOriginal source
UTILITY OF CALCULATED GLOMERULAR FILTRATION RATE IN EVALUATION OF KIDNEY FUNCTION — Research Paper | ScholarLens