2011•Artificial OrgansRequires access

Analysis of Pulsatile and Nonpulsatile Blood Flow Effects in Different Degrees of Stenotic Vasculature

Jae Seung Jung, Kuk Hui Son, Chi Bum Ahn, Jung Joo Lee, Ho Sung Son, Kyung Sun

Open publisher page 5 citations

Abstract

Vessel lumens that have been chronically narrowed by atherosclerosis should be increased in flow velocity and intrastenotic area pressure to maintain an equal flow. This might be followed by a decrease in hemodynamic energy, leading to a reduction of tissue perfusion. In this study, we compared hemodynamic energies according to degrees of stenotic vasculature between pulsatile flow and nonpulsatile flow. Cannuale with 25, 50, and 75% diameter stenosis (DS) were located at the outlet cannula. Using the Korea Hybrid ventricular assist device (KH-VAD) (pulsatile pump: group A) and Biopump (nonpulsatile pump: group B), constant flow of 2 L/min was maintained then real-time flow and velocity in the proximal and distal part of the stenotic cannula were measured. The hemodynamic energies of two groups were compared. At 75% DS, proximal energy equivalent pressure (EEP) delivered to the distal end was only 41.9% (group A) and 42.5% (group B). As the percent EEP fell below 10%, pulsatility disappeared from the 50% stenosis in group A. The surplus hemodynamic energy (SHE) of group B at all degrees of stenosis must have been 0, which was also the case of group A at 75% stenosis. This research evaluated the hemodynamic energy on various degrees of DS in both pulsatile and nonpulsatile flow with mock system. Using a pulsatile pump, pulsatility disappeared above 50% DS while hemodynamic energy was maintained. Therefore, our results suggest that pulsatile flow has a better effect than nonpulsatile flow in reserving hemodynamic energy after stenotic lesion.

About this research paper

What this paper is about

Vessel lumens that have been chronically narrowed by atherosclerosis should be increased in flow velocity and intrastenotic area pressure to maintain an equal flow. This might be followed by a decrease in hemodynamic energy, leading to a reduction of tissue perfusion. In this study, we compared hemodynamic energies according to degrees of stenotic vasculature between pulsatile flow and nonpulsatile flow. Cannuale with 25, 50, and 75% diameter stenosis (DS) were located at the outlet cannula. Using the Korea Hybrid ventricular assist device (KH-VAD) (pulsatile pump: group A) and Biopump (nonpulsatile pump: group B), constant flow of 2 L/min was maintained then real-time flow and velocity in the proximal and distal part of the stenotic cannula were measured. The hemodynamic energies of two groups were compared. At 75% DS, proximal energy equivalent pressure (EEP) delivered to the distal end was only 41.9% (group A) and 42.5% (group B). As the percent EEP fell below 10%, pulsatility disappeared from the 50% stenosis in group A. The surplus hemodynamic energy (SHE) of group B at all degrees of stenosis must have been 0, which was also the case of group A at 75% stenosis. This research evaluated the hemodynamic energy on various degrees of DS in both pulsatile and nonpulsatile flow with mock system. Using a pulsatile pump, pulsatility disappeared above 50% DS while hemodynamic energy was maintained. Therefore, our results suggest that pulsatile flow has a better effect than nonpulsatile flow in reserving hemodynamic energy after stenotic lesion.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Vessel lumens that have been chronically narrowed by atherosclerosis should be increased in flow velocity and intrastenotic area pressure to maintain an equal flow. This might be followed by a decrease in hemodynamic energy, leading to a reduction of tissue perfusion. In this study, we compared hemodynamic energies according to degrees of stenotic vasculature between pulsatile flow and nonpulsatile flow. Cannuale with 25, 50, and 75% diameter stenosis (DS) were located at the outlet cannula. Using the Korea Hybrid ventricular assist device (KH-VAD) (pulsatile pump: group A) and Biopump (nonpulsatile pump: group B), constant flow of 2 L/min was maintained then real-time flow and velocity in the proximal and distal part of the stenotic cannula were measured. The hemodynamic energies of two groups were compared. At 75% DS, proximal energy equivalent pressure (EEP) delivered to the distal end was only 41.9% (group A) and 42.5% (group B). As the percent EEP fell below 10%, pulsatility disappeared from the 50% stenosis in group A. The surplus hemodynamic energy (SHE) of group B at all degrees of stenosis must have been 0, which was also the case of group A at 75% stenosis. This research evaluated the hemodynamic energy on various degrees of DS in both pulsatile and nonpulsatile flow with mock system. Using a pulsatile pump, pulsatility disappeared above 50% DS while hemodynamic energy was maintained. Therefore, our results suggest that pulsatile flow has a better effect than nonpulsatile flow in reserving hemodynamic energy after stenotic lesion.

Key concepts: Pulsatile flow, Hemodynamics, Stenosis, Cannula, Medicine, Blood flow, Internal medicine, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of Pulsatile and Nonpulsatile Blood Flow Effects in Different Degrees of Stenotic Vasculature — Research Paper | ScholarLens