2012•Journal of Liquid Chromatography & Related TechnologiesRequires access

SYNTHESIS AND APPLICATION OF MOLECULARLY IMPRINTED POLYMERS FOR SOLID-PHASE EXTRACTION OF DIPYRIDAMOLE FROM COMPLEX BIOLOGICAL FLUIDS

Mehran Javanbakht, Somayeh Mohammadi, Behrouz Akbari‐adergani

Open publisher page 7 citations

Abstract

In this study, a novel sample clean-up technique based on the molecularly imprinted solid-phase extraction (MISPE) procedure is described for the determination of dipyridamole (DIP) in biological fluids. The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, and DIP as the template molecule in chloroform. The novel imprinted polymer was used as a solid-phase extraction sorbent for the extraction of DIP from human serum and urine. Various parameters affecting the extraction efficiency of the polymer were evaluated. The optimal conditions for molecularly imprinted solid-phase extraction of the cartridges were obtained. The MIP selectivity was evaluated by checking several substances with similar molecular structures to the template. The limit of detection (LOD) and limit of quantification (LOQ) for DIP in urine samples were 1.6 and 4.0 µg L−1, respectively. These limits for DIP in serum samples were 2.5 and 6.2 µg L−1, respectively. The recoveries for serum and urine samples were higher than 80.0 and 83.0%, respectively.

About this research paper

What this paper is about

In this study, a novel sample clean-up technique based on the molecularly imprinted solid-phase extraction (MISPE) procedure is described for the determination of dipyridamole (DIP) in biological fluids. The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, and DIP as the template molecule in chloroform. The novel imprinted polymer was used as a solid-phase extraction sorbent for the extraction of DIP from human serum and urine. Various parameters affecting the extraction efficiency of the polymer were evaluated. The optimal conditions for molecularly imprinted solid-phase extraction of the cartridges were obtained. The MIP selectivity was evaluated by checking several substances with similar molecular structures to the template. The limit of detection (LOD) and limit of quantification (LOQ) for DIP in urine samples were 1.6 and 4.0 µg L−1, respectively. These limits for DIP in serum samples were 2.5 and 6.2 µg L−1, respectively. The recoveries for serum and urine samples were higher than 80.0 and 83.0%, respectively.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, a novel sample clean-up technique based on the molecularly imprinted solid-phase extraction (MISPE) procedure is described for the determination of dipyridamole (DIP) in biological fluids. The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, and DIP as the template molecule in chloroform. The novel imprinted polymer was used as a solid-phase extraction sorbent for the extraction of DIP from human serum and urine. Various parameters affecting the extraction efficiency of the polymer were evaluated. The optimal conditions for molecularly imprinted solid-phase extraction of the cartridges were obtained. The MIP selectivity was evaluated by checking several substances with similar molecular structures to the template. The limit of detection (LOD) and limit of quantification (LOQ) for DIP in urine samples were 1.6 and 4.0 µg L−1, respectively. These limits for DIP in serum samples were 2.5 and 6.2 µg L−1, respectively. The recoveries for serum and urine samples were higher than 80.0 and 83.0%, respectively.

Key concepts: Molecularly imprinted polymer, Ethylene glycol dimethacrylate, Solid phase extraction, Chemistry, Chromatography, Detection limit, Methacrylic acid, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
SYNTHESIS AND APPLICATION OF MOLECULARLY IMPRINTED POLYMERS FOR SOLID-PHASE EXTRACTION OF DIPYRIDAMOLE FROM COMPLEX BIOLOGICAL FLUIDS — Research Paper | ScholarLens