2014Unpublished venueRequires access

On-line monitoring of winding parameters for single-phase transformers

P. Amruta Reddy, Bharat Singh Rajpurohit

Open publisher page 10 citations

Abstract

The condition of transformer windings can be gauged by monitoring their equivalent circuit parameters. These parameters are not affected by external faults and change only in the presence of an internal aberration. Changes in the insulation temperature are reflected in winding temperature and can be monitored by observing the winding resistance values. Similarly changes in the short circuit reactance can give information on the condition and structure of windings. Rapid and reliable protection can be implemented by monitoring these parameters since inrush current and over-excitation does not affect these parameters. Presently, there is no accurate measurement method for the transformer winding parameters and generally require the transformer to be disconnected from the power system. A new simple algorithm for extracting transformer winding parameters which can be implemented online is presented in this paper. This method takes only the input currents and voltages as inputs and thereby eliminates the need for the disconnection of the transformer from the power system. In this method, winding parameters are obtained by solving the equivalent circuit equations in real time continuously which allows for interpretation and detection of faults in real-time. The proposed method has been tested and validated by simulations.

About this research paper

What this paper is about

The condition of transformer windings can be gauged by monitoring their equivalent circuit parameters. These parameters are not affected by external faults and change only in the presence of an internal aberration. Changes in the insulation temperature are reflected in winding temperature and can be monitored by observing the winding resistance values. Similarly changes in the short circuit reactance can give information on the condition and structure of windings. Rapid and reliable protection can be implemented by monitoring these parameters since inrush current and over-excitation does not affect these parameters. Presently, there is no accurate measurement method for the transformer winding parameters and generally require the transformer to be disconnected from the power system. A new simple algorithm for extracting transformer winding parameters which can be implemented online is presented in this paper. This method takes only the input currents and voltages as inputs and thereby eliminates the need for the disconnection of the transformer from the power system. In this method, winding parameters are obtained by solving the equivalent circuit equations in real time continuously which allows for interpretation and detection of faults in real-time. The proposed method has been tested and validated by simulations.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The condition of transformer windings can be gauged by monitoring their equivalent circuit parameters. These parameters are not affected by external faults and change only in the presence of an internal aberration. Changes in the insulation temperature are reflected in winding temperature and can be monitored by observing the winding resistance values. Similarly changes in the short circuit reactance can give information on the condition and structure of windings. Rapid and reliable protection can be implemented by monitoring these parameters since inrush current and over-excitation does not affect these parameters. Presently, there is no accurate measurement method for the transformer winding parameters and generally require the transformer to be disconnected from the power system. A new simple algorithm for extracting transformer winding parameters which can be implemented online is presented in this paper. This method takes only the input currents and voltages as inputs and thereby eliminates the need for the disconnection of the transformer from the power system. In this method, winding parameters are obtained by solving the equivalent circuit equations in real time continuously which allows for interpretation and detection of faults in real-time. The proposed method has been tested and validated by simulations.

Key concepts: Inrush current, Reactance, Leakage inductance, Electromagnetic coil, Autotransformer, Delta-wye transformer, Transformer, Rotary variable differential transformer

Related papers

Back to paper searchBrowse research topicsOriginal source
On-line monitoring of winding parameters for single-phase transformers — Research Paper | ScholarLens