Central AC chilled water system is an air conditioning system that has cooling ability in more than one room. The system has two cycles consist of primary and secondary cycles. When primary cycle works, the refrigerant is used as a working fluid while in the secondary cycle process, the water is used as working fluid. To determine the heat absorbed by water, it can be done by analyzing NTU (Number of Transfer Unit) of the water chiller system. The variation of the chilled water volume rate applied in this research was from 13 l/min to 5 l/min, with the interval of 0.5 l/min. As a result, it was founded that the maximum value of NTU was 2.01, at chilled water volume rate of 12 l/min. Below that chilled water volume rate, values of NTU would decrease and stable. It can be concluded that the volume rate of chilled water influenced the value of NTU in the FCU (Fan Coil Unit) of the water chiller AC system.

About this research paper

What this paper is about

Central AC chilled water system is an air conditioning system that has cooling ability in more than one room. The system has two cycles consist of primary and secondary cycles. When primary cycle works, the refrigerant is used as a working fluid while in the secondary cycle process, the water is used as working fluid. To determine the heat absorbed by water, it can be done by analyzing NTU (Number of Transfer Unit) of the water chiller system. The variation of the chilled water volume rate applied in this research was from 13 l/min to 5 l/min, with the interval of 0.5 l/min. As a result, it was founded that the maximum value of NTU was 2.01, at chilled water volume rate of 12 l/min. Below that chilled water volume rate, values of NTU would decrease and stable. It can be concluded that the volume rate of chilled water influenced the value of NTU in the FCU (Fan Coil Unit) of the water chiller AC system.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Central AC chilled water system is an air conditioning system that has cooling ability in more than one room. The system has two cycles consist of primary and secondary cycles. When primary cycle works, the refrigerant is used as a working fluid while in the secondary cycle process, the water is used as working fluid. To determine the heat absorbed by water, it can be done by analyzing NTU (Number of Transfer Unit) of the water chiller system. The variation of the chilled water volume rate applied in this research was from 13 l/min to 5 l/min, with the interval of 0.5 l/min. As a result, it was founded that the maximum value of NTU was 2.01, at chilled water volume rate of 12 l/min. Below that chilled water volume rate, values of NTU would decrease and stable. It can be concluded that the volume rate of chilled water influenced the value of NTU in the FCU (Fan Coil Unit) of the water chiller AC system.

Key concepts: Chilled water, Water chiller, Fan coil unit, Refrigerant, Volume (thermodynamics), Chiller, Volumetric flow rate, Water cooling

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental Analysis of Volume Flow Rate in Water Chiller Type of Central AC System — Research Paper | ScholarLens