2004Journal of Cataract & Refractive SurgeryRequires access

Opposite clear corneal incisions on the steep meridian in phacoemulsification

Athanassius Tadros, Maged Habib, Deepak Tejwani, Hirut Von Lany, Peter Thomas

Open publisher page 38 citations

Abstract

PURPOSE: To evaluate the effect of on-axis opposite clear corneal incisions (OCCIs) in phacoemulsification on reducing preoperative corneal astigmatism and to predict the astigmatic outcome of the incisions. SETTING: Royal Eye Infirmary, Dorset County Hospital, and Winterbourne Hospital, Dorchester, Dorset, and the Department of Ophthalmology, East Somerset Hospital, Yeovil, Somerset, United Kingdom. METHODS: This prospective study included all patients (n = 103) who had on-axis OCCIs as a part of routine phacoemulsification with foldable intraocular lens (IOL) implantation performed by 1 surgeon during 2000. Keratometry was done 6 to 8 weeks postoperatively. The differences in the preoperative and postoperative corneal astigmatism and corneal spherical equivalent (SE) were recorded. Surgically induced astigmatism (SIA) was calculated using vector analysis. RESULTS: The mean reduction in corneal astigmatism was 0.50 diopter (D) (P<.001). The mean SIA was 1.57 D (95% confidence interval [CI], 1.42 to 1.71). There was a weak association between the SIA and the patient's age and axis of preoperative astigmatism. The mean change in SE was +0.02 D (95% CI, -0.08 to +0.12). CONCLUSIONS: Results indicate that on-axis OCCIs are a reliable and practical way of reducing preexisting corneal astigmatism. The change in SE was negligible and thus can be ignored during biometry.

About this research paper

What this paper is about

PURPOSE: To evaluate the effect of on-axis opposite clear corneal incisions (OCCIs) in phacoemulsification on reducing preoperative corneal astigmatism and to predict the astigmatic outcome of the incisions. SETTING: Royal Eye Infirmary, Dorset County Hospital, and Winterbourne Hospital, Dorchester, Dorset, and the Department of Ophthalmology, East Somerset Hospital, Yeovil, Somerset, United Kingdom. METHODS: This prospective study included all patients (n = 103) who had on-axis OCCIs as a part of routine phacoemulsification with foldable intraocular lens (IOL) implantation performed by 1 surgeon during 2000. Keratometry was done 6 to 8 weeks postoperatively. The differences in the preoperative and postoperative corneal astigmatism and corneal spherical equivalent (SE) were recorded. Surgically induced astigmatism (SIA) was calculated using vector analysis. RESULTS: The mean reduction in corneal astigmatism was 0.50 diopter (D) (P<.001). The mean SIA was 1.57 D (95% confidence interval [CI], 1.42 to 1.71). There was a weak association between the SIA and the patient's age and axis of preoperative astigmatism. The mean change in SE was +0.02 D (95% CI, -0.08 to +0.12). CONCLUSIONS: Results indicate that on-axis OCCIs are a reliable and practical way of reducing preexisting corneal astigmatism. The change in SE was negligible and thus can be ignored during biometry.

Why it matters

OpenAlex reports 38 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate the effect of on-axis opposite clear corneal incisions (OCCIs) in phacoemulsification on reducing preoperative corneal astigmatism and to predict the astigmatic outcome of the incisions. SETTING: Royal Eye Infirmary, Dorset County Hospital, and Winterbourne Hospital, Dorchester, Dorset, and the Department of Ophthalmology, East Somerset Hospital, Yeovil, Somerset, United Kingdom. METHODS: This prospective study included all patients (n = 103) who had on-axis OCCIs as a part of routine phacoemulsification with foldable intraocular lens (IOL) implantation performed by 1 surgeon during 2000. Keratometry was done 6 to 8 weeks postoperatively. The differences in the preoperative and postoperative corneal astigmatism and corneal spherical equivalent (SE) were recorded. Surgically induced astigmatism (SIA) was calculated using vector analysis. RESULTS: The mean reduction in corneal astigmatism was 0.50 diopter (D) (P<.001). The mean SIA was 1.57 D (95% confidence interval [CI], 1.42 to 1.71). There was a weak association between the SIA and the patient's age and axis of preoperative astigmatism. The mean change in SE was +0.02 D (95% CI, -0.08 to +0.12). CONCLUSIONS: Results indicate that on-axis OCCIs are a reliable and practical way of reducing preexisting corneal astigmatism. The change in SE was negligible and thus can be ignored during biometry.

Key concepts: Phacoemulsification, Dioptre, Medicine, Keratometer, Meridian (astronomy), Ophthalmology, Intraocular lens, Astigmatism

Related papers

Back to paper searchBrowse research topicsOriginal source
Opposite clear corneal incisions on the steep meridian in phacoemulsification — Research Paper | ScholarLens