2013•Journal of Liquid Chromatography & Related TechnologiesRequires access

RAPID AND SENSITIVE SIMULTANEOUS ESTIMATION OF METFORMIN HYDROCHLORIDE AND PIOGLITAZONE HYDROCHLORIDE IN TABLET FORMULATION BY HPTLC METHOD

Darshana K. Modi, Bhavesh H. Patel

Open publisher page 10 citations

Abstract

A rapid, simple, and sensitive HPTLC method for simultaneous estimation of two antidiabetic drugs, metformin hydrochloride and pioglitazone hydrochloride, in pharmaceutical tablet was developed and validated. Separation was achieved on aluminum sheets of silica gel 60 F254 using butanol:1, 4-dioxane:glacial acetic acid (5:3:2, v/v/v) as the mobile phase. This system gave a good resolution for metformin hydrochloride (R f value of 0.36 ± 0.01) and pioglitazone hydrochloride (R f value of 0.73 ± 0.01). Detection and quantification was carried out at 226 nm. Calibration plot was constructed in the range of 2000 to 20000 ng/band for metformin hydrochloride and 60 to 600 ng/band for pioglitazone hydrochloride. The linear regression data for the calibration plot showed a good relationship with r = 0.9960 and 0.9968 for metformin hydrochloride and pioglitazone hydrochloride, respectively. Assays for metformin hydrochloride and pioglitazone hydrochloride were 99.6% (RSD 0.618%) and 99.7% (RSD 0.511%), respectively, for the brand analyzed. The method was validated for precision and recovery. The limits of detection and quantification were 629.89 and 1908.76 ng/band for metformin hydrochloride and 8.51 and 25.77 ng/band for pioglitazone hydrochloride, respectively.

About this research paper

What this paper is about

A rapid, simple, and sensitive HPTLC method for simultaneous estimation of two antidiabetic drugs, metformin hydrochloride and pioglitazone hydrochloride, in pharmaceutical tablet was developed and validated. Separation was achieved on aluminum sheets of silica gel 60 F254 using butanol:1, 4-dioxane:glacial acetic acid (5:3:2, v/v/v) as the mobile phase. This system gave a good resolution for metformin hydrochloride (R f value of 0.36 ± 0.01) and pioglitazone hydrochloride (R f value of 0.73 ± 0.01). Detection and quantification was carried out at 226 nm. Calibration plot was constructed in the range of 2000 to 20000 ng/band for metformin hydrochloride and 60 to 600 ng/band for pioglitazone hydrochloride. The linear regression data for the calibration plot showed a good relationship with r = 0.9960 and 0.9968 for metformin hydrochloride and pioglitazone hydrochloride, respectively. Assays for metformin hydrochloride and pioglitazone hydrochloride were 99.6% (RSD 0.618%) and 99.7% (RSD 0.511%), respectively, for the brand analyzed. The method was validated for precision and recovery. The limits of detection and quantification were 629.89 and 1908.76 ng/band for metformin hydrochloride and 8.51 and 25.77 ng/band for pioglitazone hydrochloride, respectively.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A rapid, simple, and sensitive HPTLC method for simultaneous estimation of two antidiabetic drugs, metformin hydrochloride and pioglitazone hydrochloride, in pharmaceutical tablet was developed and validated. Separation was achieved on aluminum sheets of silica gel 60 F254 using butanol:1, 4-dioxane:glacial acetic acid (5:3:2, v/v/v) as the mobile phase. This system gave a good resolution for metformin hydrochloride (R f value of 0.36 ± 0.01) and pioglitazone hydrochloride (R f value of 0.73 ± 0.01). Detection and quantification was carried out at 226 nm. Calibration plot was constructed in the range of 2000 to 20000 ng/band for metformin hydrochloride and 60 to 600 ng/band for pioglitazone hydrochloride. The linear regression data for the calibration plot showed a good relationship with r = 0.9960 and 0.9968 for metformin hydrochloride and pioglitazone hydrochloride, respectively. Assays for metformin hydrochloride and pioglitazone hydrochloride were 99.6% (RSD 0.618%) and 99.7% (RSD 0.511%), respectively, for the brand analyzed. The method was validated for precision and recovery. The limits of detection and quantification were 629.89 and 1908.76 ng/band for metformin hydrochloride and 8.51 and 25.77 ng/band for pioglitazone hydrochloride, respectively.

Key concepts: Pioglitazone, Metformin Hydrochloride, Chromatography, Chemistry, Detection limit, Hydrochloride, Calibration curve, Silica gel

Related papers

Back to paper searchBrowse research topicsOriginal source
RAPID AND SENSITIVE SIMULTANEOUS ESTIMATION OF METFORMIN HYDROCHLORIDE AND PIOGLITAZONE HYDROCHLORIDE IN TABLET FORMULATION BY HPTLC METHOD — Research Paper | ScholarLens