2011EchocardiographyOpen access

Transthoracic Echocardiography Guidance during Percutaneous Closure of Patent Foramen Ovale

Ali̇ Oto, Kudret Aytemir, Süheyla Özkutlu, Ergün Barış Kaya, Hikmet Yorgun, Uğur Canpolat, Ahmet Hakan Ateş, H. Özkutlu

Open full text 15 citations

Abstract

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) has been increasingly performed for several indications; mostly due to cryptogenic stroke. In this study we aimed to evaluate the safety and efficacy of transthoracic echocardiographic (TTE) guidance during percutaneous closure of PFO in using the Amplatzer and Occlutech Figulla PFO occluder devices. METHODS: Between October 2005 and March 2011, 139 patients (74 male, mean age: 40.4 ± 10.3) underwent transcatheter PFO closure. In all patients transesophageal echocardiography performed subsequently to diagnose, assess the size and evaluate for suitability of the defect for percutaneous closure. During the procedure fluoroscopy and TTE were used for guidance. RESULTS: Among 139 patients, Amplatzer PFO occluder was used in 74 patients and in 65 of them Occlutech Figulla device was selected for occlusion. The indications for PFO closure were ischemic stroke in 98 (70.5%), recurrent transient ischemic attacks (TIA) in 40 (28.7%), peripheral embolism in 1 (0.8%) of the patients. In all patients, percutaneous intervention was performed successfully under TTE guidance. There have been no neurologic (recurrent strokes or TIAs) and cardiovascular complications during the immediate and long-term follow-up period (2-67 months, median 29). There was significant difference between the mean fluoroscopic time from the beginning which is 8.6 ± 3.4 min in the former versus 3.4 ± 1.9 min in the latter (P < 0.05). CONCLUSION: Our study confirms the efficacy and safety of TTE guidance during percutaneous closure of PFO, which shortens the procedural time and obviates the need for general anesthesia or endotracheal intubation.

About this research paper

What this paper is about

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) has been increasingly performed for several indications; mostly due to cryptogenic stroke. In this study we aimed to evaluate the safety and efficacy of transthoracic echocardiographic (TTE) guidance during percutaneous closure of PFO in using the Amplatzer and Occlutech Figulla PFO occluder devices. METHODS: Between October 2005 and March 2011, 139 patients (74 male, mean age: 40.4 ± 10.3) underwent transcatheter PFO closure. In all patients transesophageal echocardiography performed subsequently to diagnose, assess the size and evaluate for suitability of the defect for percutaneous closure. During the procedure fluoroscopy and TTE were used for guidance. RESULTS: Among 139 patients, Amplatzer PFO occluder was used in 74 patients and in 65 of them Occlutech Figulla device was selected for occlusion. The indications for PFO closure were ischemic stroke in 98 (70.5%), recurrent transient ischemic attacks (TIA) in 40 (28.7%), peripheral embolism in 1 (0.8%) of the patients. In all patients, percutaneous intervention was performed successfully under TTE guidance. There have been no neurologic (recurrent strokes or TIAs) and cardiovascular complications during the immediate and long-term follow-up period (2-67 months, median 29). There was significant difference between the mean fluoroscopic time from the beginning which is 8.6 ± 3.4 min in the former versus 3.4 ± 1.9 min in the latter (P < 0.05). CONCLUSION: Our study confirms the efficacy and safety of TTE guidance during percutaneous closure of PFO, which shortens the procedural time and obviates the need for general anesthesia or endotracheal intubation.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) has been increasingly performed for several indications; mostly due to cryptogenic stroke. In this study we aimed to evaluate the safety and efficacy of transthoracic echocardiographic (TTE) guidance during percutaneous closure of PFO in using the Amplatzer and Occlutech Figulla PFO occluder devices. METHODS: Between October 2005 and March 2011, 139 patients (74 male, mean age: 40.4 ± 10.3) underwent transcatheter PFO closure. In all patients transesophageal echocardiography performed subsequently to diagnose, assess the size and evaluate for suitability of the defect for percutaneous closure. During the procedure fluoroscopy and TTE were used for guidance. RESULTS: Among 139 patients, Amplatzer PFO occluder was used in 74 patients and in 65 of them Occlutech Figulla device was selected for occlusion. The indications for PFO closure were ischemic stroke in 98 (70.5%), recurrent transient ischemic attacks (TIA) in 40 (28.7%), peripheral embolism in 1 (0.8%) of the patients. In all patients, percutaneous intervention was performed successfully under TTE guidance. There have been no neurologic (recurrent strokes or TIAs) and cardiovascular complications during the immediate and long-term follow-up period (2-67 months, median 29). There was significant difference between the mean fluoroscopic time from the beginning which is 8.6 ± 3.4 min in the former versus 3.4 ± 1.9 min in the latter (P < 0.05). CONCLUSION: Our study confirms the efficacy and safety of TTE guidance during percutaneous closure of PFO, which shortens the procedural time and obviates the need for general anesthesia or endotracheal intubation.

Key concepts: Medicine, Patent foramen ovale, Percutaneous, Fluoroscopy, Paradoxical embolism, Stroke (engine), Foramen ovale (heart), Embolism