1989Fusion TechnologyRequires access

LOCA Study for a Helium-Cooled Solid Breeder Design for ITER

Z. R. Gorbis, A.R. Raffray, Kaoru Fujimura, Insoo Jun, Mohamed Abdou

Open publisher page 5 citations

Abstract

The analysis of thermal processes after a loss-of-coolant accident (LOCA) in a solid breeder blanket is important because of the first wall and solid breeder maximum allowable temperature constraints. The objective is to design for a LOCA so that following a LOCA, the maximum solid breeder and structure temperatures are less than the limit beyond which irreversible damage is done, which would lead to loss of investment. The temporal temperature profiles for the solid breeder and first wall regions of a helium-cooled solid breeder design for ITER were calculated based on afterheat values for adiabatic and non-adiabatic conditions and the results are presented in this paper. It is found that, for this design, even when excluding radiation to the cooled inboard, a LOCA can be accommodated by energy removal through a flowing purge with a reasonable flow rate.

About this research paper

What this paper is about

The analysis of thermal processes after a loss-of-coolant accident (LOCA) in a solid breeder blanket is important because of the first wall and solid breeder maximum allowable temperature constraints. The objective is to design for a LOCA so that following a LOCA, the maximum solid breeder and structure temperatures are less than the limit beyond which irreversible damage is done, which would lead to loss of investment. The temporal temperature profiles for the solid breeder and first wall regions of a helium-cooled solid breeder design for ITER were calculated based on afterheat values for adiabatic and non-adiabatic conditions and the results are presented in this paper. It is found that, for this design, even when excluding radiation to the cooled inboard, a LOCA can be accommodated by energy removal through a flowing purge with a reasonable flow rate.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The analysis of thermal processes after a loss-of-coolant accident (LOCA) in a solid breeder blanket is important because of the first wall and solid breeder maximum allowable temperature constraints. The objective is to design for a LOCA so that following a LOCA, the maximum solid breeder and structure temperatures are less than the limit beyond which irreversible damage is done, which would lead to loss of investment. The temporal temperature profiles for the solid breeder and first wall regions of a helium-cooled solid breeder design for ITER were calculated based on afterheat values for adiabatic and non-adiabatic conditions and the results are presented in this paper. It is found that, for this design, even when excluding radiation to the cooled inboard, a LOCA can be accommodated by energy removal through a flowing purge with a reasonable flow rate.

Key concepts: Breeder (animal), Blanket, Nuclear engineering, Helium, Materials science, Loss-of-coolant accident, Breeder reactor, Adiabatic process

Related papers

Back to paper searchBrowse research topicsOriginal source
LOCA Study for a Helium-Cooled Solid Breeder Design for ITER — Research Paper | ScholarLens