2012IET Power ElectronicsRequires access

Analysis and design of different control strategies of hybrid active power filter based on the state model

Salvador Pérez Litrán, P. Salmerón

Open publisher page 39 citations

Abstract

A configuration consisting of a combination of a series active power filter (APF) and a parallel passive filter is shown to be an efficient system for non-linear load compensation. For this topology, different compensation strategies are proposed to control the series APF. The most effective strategies determine the APF compensation voltage in proportion to the source current harmonics. The proportionality constant ‘k’ in the control algorithm implementation is related to the APF gain and complete system dynamic. In this study, the system state model is obtained for three control strategies of series APF: compensation voltage proportional to source current harmonics, compensation voltage opposite to the load voltage harmonics and a hybrid strategy which combines both previous strategies. The analyses of the resulting models provide the information needed to establish design criteria with respect to harmonic filtering and system stability. The methodology proposed in this study eliminates the arbitrary choice of the proportionality constant. The three strategies were analysed in two different situations: sinusoidal supply voltages and distorted supply voltages. Finally, results of an experimental prototype developed for this purpose allowed the proposed analysis to be verified.

About this research paper

What this paper is about

A configuration consisting of a combination of a series active power filter (APF) and a parallel passive filter is shown to be an efficient system for non-linear load compensation. For this topology, different compensation strategies are proposed to control the series APF. The most effective strategies determine the APF compensation voltage in proportion to the source current harmonics. The proportionality constant ‘k’ in the control algorithm implementation is related to the APF gain and complete system dynamic. In this study, the system state model is obtained for three control strategies of series APF: compensation voltage proportional to source current harmonics, compensation voltage opposite to the load voltage harmonics and a hybrid strategy which combines both previous strategies. The analyses of the resulting models provide the information needed to establish design criteria with respect to harmonic filtering and system stability. The methodology proposed in this study eliminates the arbitrary choice of the proportionality constant. The three strategies were analysed in two different situations: sinusoidal supply voltages and distorted supply voltages. Finally, results of an experimental prototype developed for this purpose allowed the proposed analysis to be verified.

Why it matters

OpenAlex reports 39 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A configuration consisting of a combination of a series active power filter (APF) and a parallel passive filter is shown to be an efficient system for non-linear load compensation. For this topology, different compensation strategies are proposed to control the series APF. The most effective strategies determine the APF compensation voltage in proportion to the source current harmonics. The proportionality constant ‘k’ in the control algorithm implementation is related to the APF gain and complete system dynamic. In this study, the system state model is obtained for three control strategies of series APF: compensation voltage proportional to source current harmonics, compensation voltage opposite to the load voltage harmonics and a hybrid strategy which combines both previous strategies. The analyses of the resulting models provide the information needed to establish design criteria with respect to harmonic filtering and system stability. The methodology proposed in this study eliminates the arbitrary choice of the proportionality constant. The three strategies were analysed in two different situations: sinusoidal supply voltages and distorted supply voltages. Finally, results of an experimental prototype developed for this purpose allowed the proposed analysis to be verified.

Key concepts: Harmonics, Control theory (sociology), Compensation (psychology), Active filter, Voltage, Harmonic, Voltage source, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis and design of different control strategies of hybrid active power filter based on the state model — Research Paper | ScholarLens